[[File:TM5006.jpg | right | thumb | 300px]]
{{Instrument Sidebar
[[File:TM5006 rear.jpg | right | thumb | 300px ]]
|manufacturer=Tektronix
|model=TM5006
|class=Mainframe
|series=TM5000
|summary=six-bay mainframe
|image=TM5006.jpg
|caption=TM5006 front
|introduced=1982
|discontinued=(?)
|designers=
|manuals=
* [[Media:070-2950-00.pdf|TM5006 Instruction Manual 070-2950-00]] (en/fr/de/jp, OCR)<br /><small>[[Media:070-2950-00_2.pdf|Alternate (lower res)]]</small>
* [[Media:070-7614-03.pdf|TM5006A Instruction Manual 070-7614-03]]<br /><small>[[Media:070-7614-03 (2).pdf|Alternate (schematics missing)]]</small>
}}
[[File:TM5006 rear.jpg | right | thumb | 250px ]]
The '''Tektronix TM5006''' is a six-bay mainframe with a [[GPIB interface]] for the [[TM5000 system]].   
The '''Tektronix TM5006''' is a six-bay mainframe with a [[GPIB interface]] for the [[TM5000 system]].   


The rightmost compartment (slot 6) can supply [[TM500 high-power compartments|high-powered plugins]].
The rightmost compartment (slot 6) can supply [[TM500 high-power compartments|high-powered plugins]].


The DC rails to the plugins are provided by a switchmode PSU. DC rails are 8V 26V and -26V.  The case has a cooling fan which is connected to the PRIMARY of the transformer.
The DC rails to the plugins are provided by a switch-mode PSU. The supply is not universal input voltage, the input voltage must be set with two internal jumpers. DC rails are 8 V, +26 V, and −26 V.  The case has a cooling fan which is connected to the primary of the transformer.


Available options include 02 Rear Inputs and 10 a set of 19-inch rackmount slides.
Available options include Opt.02, Rear Inputs, and Opt.10, a set of 19-inch rackmount slides.


For option 02 six rear BNC connectors and a 50 pin standard 50 pin female dsub connector will be installed on the rear panel. In addition internal pin headers will be soldered internally. No internal wiring is provided.
For option 02, six BNC connectors and a 50-pin female [[D-sub connector|DD-50 D-sub connector]] are installed on the rear panel and pin headers soldered internally, but no internal wiring is pre-installed.


The rack-mount kit has different sides compared to the standard model. It is not possible remove the standard carry handle to install a rack-mount kit. The entire side panel must be swapped.
The rack-mount kit has different sides compared to the standard model. It is not possible to remove the standard carry handle to install a rack-mount kit. The entire side panel must be swapped.
 
==Manuals==
* [http://w140.com/smb/TM5006_SM.pdf Tektronix TM5006 Manual Small (OCR, PDF)]
* [http://w140.com/smb/TM5006_LG.pdf Tektronix TM5006 Manual Large (OCR, PDF)]


==Specifications==
==Specifications==
[[Category:Specifications needed]] ''please add''
[[Category:Specifications needed]] ''please add''
Input Voltage 115 V or 230 V nominal (selected with an internal jumper) with options for high, medium or low (100 V 110 V 120 V) or (200 V 220 V 240 V) using a second internal jumper.
Fan Flow Rate is higher in units with the 02 (rack-mount) option


==Links==
==Links==
* [http://www.barrytech.com/tektronix/tektm500/tektm5006.html TM5006] / [http://www.barrytech.com/tektronix/tektm500/tektm5006a.html TM5006A] @ barrytech.com
* [http://www.barrytech.com/tektronix/tektm500/tektm5006.html TM5006] / [http://www.barrytech.com/tektronix/tektm500/tektm5006a.html TM5006A] @ barrytech.com
* [https://www.youtube.com/watch?v=qanMqO5gEeE Zenwizard Studios Rebuild and Repair] @ Zenwizard Studios You Tube
* [https://www.youtube.com/watch?v=J7u-U7R4E18 Zenwizard Studios Rebuild and Repair II] @ Zenwizard Studios You Tube
* [https://www.youtube.com/watch?v=_HRpNxU6-S8 TM5006 Mainframe load tester] @ You Tube


==Pictures==
<gallery>
<gallery>
Tek tm5006 plug-in bay.jpg
Tek tm5006 plug-in bay.jpg

Latest revision as of 04:11, 4 October 2023

Tektronix TM5006
six-bay mainframe
TM5006 front

Produced from 1982 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix TM5006 is a six-bay mainframe with a GPIB interface for the TM5000 system.

The rightmost compartment (slot 6) can supply high-powered plugins.

The DC rails to the plugins are provided by a switch-mode PSU. The supply is not universal input voltage, the input voltage must be set with two internal jumpers. DC rails are 8 V, +26 V, and −26 V. The case has a cooling fan which is connected to the primary of the transformer.

Available options include Opt.02, Rear Inputs, and Opt.10, a set of 19-inch rackmount slides.

For option 02, six BNC connectors and a 50-pin female DD-50 D-sub connector are installed on the rear panel and pin headers soldered internally, but no internal wiring is pre-installed.

The rack-mount kit has different sides compared to the standard model. It is not possible to remove the standard carry handle to install a rack-mount kit. The entire side panel must be swapped.

Specifications

please add

Input Voltage 115 V or 230 V nominal (selected with an internal jumper) with options for high, medium or low (100 V 110 V 120 V) or (200 V 220 V 240 V) using a second internal jumper.

Fan Flow Rate is higher in units with the 02 (rack-mount) option

Links

Pictures