Telequipment D755: Difference between revisions
mNo edit summary |
No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Telequipment | |||
summary=50 MHz scope | | |series= | ||
image=TQ_D755_OPT_66_front_cropped.jpg | | |model=D755 | ||
caption=Telequipment D755 with [[Telequipment V4|V4]] and [[Telequipment S2 | S2C]] plug-ins | | |summary=50 MHz scope | ||
introduced=(?) | | |image=TQ_D755_OPT_66_front_cropped.jpg | ||
discontinued=(?) | | |caption=Telequipment D755 with [[Telequipment V4|V4]] and [[Telequipment S2 | S2C]] plug-ins | ||
manuals= | |introduced=(?) | ||
* [[Media: | |discontinued=(?) | ||
|designers= | |||
|manuals= | |||
* [[Media:070-1487-10.pdf | D755 Instruction Manual]] (PDF) | |||
}} | }} | ||
The '''Telequipment D755 opt 66''' is a 50 MHz scope. It is a government version of the [[Telequipment D75]] with the addition of an XY-mode. | The '''Telequipment D755 opt 66''' is a 50 MHz scope. It is a government version of the [[Telequipment D75]] with the addition of an XY-mode. | ||
Line 16: | Line 19: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | DC to 50 MHz (−3 dB), AC cutoff 2 Hz }} | {{Spec | Bandwidth | DC to 50 MHz (−3 dB), AC cutoff 2 Hz }} | ||
{{Spec | Rise time | 7 ns | {{Spec | Rise time | 7 ns }} | ||
{{Spec | Deflection | {{Spec | Deflection | 5 mV/div to 20 V/div in 12 calibrated steps (1−2−5) }} | ||
{{Spec | Timebase A | 2 s/div to 100 ns/div in 23 calibrated steps (1−2−5 ) }} | {{Spec | Timebase A | 2 s/div to 100 ns/div in 23 calibrated steps (1−2−5 ) }} | ||
{{Spec | Timebase B | 1 s/div to 100 ns/div in 22 calibrated steps (1−2−5 ) }} | {{Spec | Timebase B | 1 s/div to 100 ns/div in 22 calibrated steps (1−2−5 ) }} | ||
Line 30: | Line 33: | ||
{{Spec | Calibrator | ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency}} | {{Spec | Calibrator | ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency}} | ||
{{Spec | CRT | [[154-0676-10]] tube, P31 [[phosphor]], 15 kV acceleration, 8 cm × 10 cm graticule }} | {{Spec | CRT | [[154-0676-10]] tube, P31 [[phosphor]], 15 kV acceleration, 8 cm × 10 cm graticule }} | ||
{{Spec | | {{Spec | Power | 100 V − 125 V in 5V steps, 200 V − 250 V in 10 V steps, selected via primary voltage selector, 40 Hz to 400 Hz, 85 VA }} | ||
{{Spec | Dimensions and Weight | 136 mm × 380 mm × 470 mm (H×W×D), 11.4 kg }} | |||
{{Spec | Dimensions and Weight | | |||
{{EndSpecs}} | {{EndSpecs}} | ||
Latest revision as of 04:06, 10 August 2021
The Telequipment D755 opt 66 is a 50 MHz scope. It is a government version of the Telequipment D75 with the addition of an XY-mode.
The D755 takes two plug-ins that are also compatible with D83, D75, D63 and DM63. Vertical plugins include the V4 dual trace amplifiers, the V3 single channel differential amplifier, the V1 single channel amplifier, and the V5 single channel amplifier with delay line. Timebase plugins include the S1 single timebase and S2C dual timebase. The preinstalled plugins in the D755 are the V4 dual trace amplifiers and the S2C dual timebase. Calibration fixtures include the 067-0672-00 plug-in for the vertical slot and the 067-0673-00 plug-in for the horizontal slot.
Key Specifications
Bandwidth | DC to 50 MHz (−3 dB), AC cutoff 2 Hz |
---|---|
Rise time | 7 ns |
Deflection | 5 mV/div to 20 V/div in 12 calibrated steps (1−2−5) |
Timebase A | 2 s/div to 100 ns/div in 23 calibrated steps (1−2−5 ) |
Timebase B | 1 s/div to 100 ns/div in 22 calibrated steps (1−2−5 ) |
Trigger Modes Timebase A | Auto, DC, AC, HF Reject |
Trigger Modes Timebase B | Auto, AC |
Trigger Sources | CH1, CH2, Alternate |
Input Voltage | max. 400 V DC + AC peak |
Input Impedance | 1 MΩ // 29 pF |
Operating Modes | CH1, CH2, CH1/CH2 Alt, Chopped, CH1 and CH2 added, CH2 inverted , X/Y-mode |
Sweep Modes | A only, A intensified by B, B delayed by A, A and B mixed, delayed B variable or triggered, repetitive or single shot |
Delay Time | 10 µs to 20 s |
Calibrator | ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency |
CRT | 154-0676-10 tube, P31 phosphor, 15 kV acceleration, 8 cm × 10 cm graticule |
Power | 100 V − 125 V in 5V steps, 200 V − 250 V in 10 V steps, selected via primary voltage selector, 40 Hz to 400 Hz, 85 VA |
Dimensions and Weight | 136 mm × 380 mm × 470 mm (H×W×D), 11.4 kg |
Internals
According to this posting, the CRT is a 154-0676-10 Tektronix CRT, the same as in the 465.
Pictures
-
Telequipment D75 opt 66 with V4 amplifier and S2C dual sweep unit