* [[Media:070-4119-00.pdf|Tektronix 2337 Operators Manual]] (OCR) | |||
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] | * [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] | ||
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] ( | * [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (bad-OCR) | ||
}} | }} | ||
The '''Tektronix 2337''' is a ruggedized portable dual-channel, 100 MHz analog scope. An A Ext connector (external signal to the A Trigger Generator) on the front panel, B Ext connector (external signal to the B Trigger Generator) on the front cover, and External Z-Axis connector at the rear round out its connectivity. The front cover also has a 3½ digit LCD for delta time (disconnects DMM from LCD readout), DC (up to 500 V), RMS AC (up to 350 V), and Ω (up to 20 MΩ) measurements, and B Trigger function. | The '''Tektronix 2337''' is a ruggedized portable dual-channel, 100 MHz analog scope. An A Ext connector (external signal to the A Trigger Generator) on the front panel, B Ext connector (external signal to the B Trigger Generator) on the front cover, and External Z-Axis connector at the rear round out its connectivity. The front cover also has a 3½ digit LCD for delta time (disconnects DMM from LCD readout), DC (up to 500 V), RMS AC (up to 350 V), and Ω (up to 20 MΩ) measurements, and B Trigger function. | ||
Line 32: | Line 32: | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | |||
{{Documents|Link=2337}} | |||
==Prices== | |||
= | {| class="wikitable" | ||
|- | |||
! Year | |||
! 1982 | |||
|- | |||
! Catalog Price | |||
| $3,350 | |||
|- | |||
! In 2023 Dollars | |||
| $10,700 | |||
|} | |||
==Pictures== | ==Pictures== | ||
Line 43: | Line 56: | ||
Tek 2337 frontclosed.JPG | Tek 2337 frontclosed.JPG | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|2337}} | |||
[[Category:2300 series scopes]] | [[Category:2300 series scopes]] | ||
[[Category:Manual needed]] | [[Category:Manual needed]] |
Latest revision as of 14:03, 27 October 2023
The Tektronix 2337 is a ruggedized portable dual-channel, 100 MHz analog scope. An A Ext connector (external signal to the A Trigger Generator) on the front panel, B Ext connector (external signal to the B Trigger Generator) on the front cover, and External Z-Axis connector at the rear round out its connectivity. The front cover also has a 3½ digit LCD for delta time (disconnects DMM from LCD readout), DC (up to 500 V), RMS AC (up to 350 V), and Ω (up to 20 MΩ) measurements, and B Trigger function.
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, ALT, CHOP (~275 kHz), ADD, CH 2, AUTO, X-Y, TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.
Trigger sources may be VERT MODE, CH 1, CH 2, LINE, EXT, and EXT ÷ 10. Trigger coupling can be AC, LF REJ, HF REJ, or DC, and can be controlled by amplitude level and slope type. The Trigger Modes may be set to AUTO, NORM, and SGL SWP.
Key Specifications
Bandwidth | 100 MHz (≥88 MHz at 2 mV/Div) |
---|---|
Deflection | CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±3%; Variable control can increase sensitivity to at least 2 mV/Div |
Input Impedance | 1 MΩ ±2% // 20 pF ±10% |
Maximum Input | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) |
Sweep | A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div |
Trigger Source | VERT MODE, CH1, CH2, LINE, EXT, EXT ÷ 10) |
Probes | Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin; One P6101A ×1 probe |
Power | 90 − 250 VAC, 48 − 440 Hz, 60 W max |
Links
Documents Referencing 2337
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1981 V13 N2.pdf | Article | Three New Portable Oscilloscopes Designed for Field Service Use | Peter Zietzke | 1981 | 2335 • 2336 • 2337 |
Prices
Year | 1982 |
---|---|
Catalog Price | $3,350 |
In 2023 Dollars | $10,700 |
Pictures
Components
Some Parts Used in the 2337
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
155-0124-00 | 155-0124-00 | Monolithic integrated circuit | horizontal preamplifier | 455 • SC503 • SC504 • 2221 • 2230 • 2232 • 2336 • 2337 |
155-0219-00 | 155-0219-00 | Hybrid integrated circuit | output amplifier | 2335 • 2336 • 2337 |
155-0220-00 | 155-0217-00 | Hybrid integrated circuit | amplifier | 2335 • 2336 • 2337 |