THS720: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Added Japanese user manual)
No edit summary
 
(6 intermediate revisions by 2 users not shown)
Line 34: Line 34:


* [[Media:3MW-10566-6.pdf|Tektronix THS700 Series Product Brochure (2006)]]
* [[Media:3MW-10566-6.pdf|Tektronix THS700 Series Product Brochure (2006)]]
==Firmware==
* [[Media:THS720_v1.03_Firmware.zip|THS720STD v1.03 Firmware]] (ZIP)
* [[Media:THS710A_v1.11_Firmware.zip|THS710A v1.11 Firmware]] (ZIP)
* [[Media:THS720x_v1.16_Firmware.zip|THS720A, THS720P v1.16 Firmware]] (ZIP)
}}
}}
The '''Tektronix THS720''' is a portable 100 MHz, 500 MS/s (each channel) dual-channel digital oscilloscope with isolated inputs.
The '''Tektronix THS720''' is a portable 100 MHz, 500 MS/s (each channel) dual-channel digital oscilloscope with isolated inputs.
Line 44: Line 48:


{{MissingSpecs}}
{{MissingSpecs}}
See [[THS720/Accessories]] for details on cables and other accessories.


==Operation==
==Operation==
Line 53: Line 59:
Recommended probes are the [[P5102]] and the [[P6113B]], both are 10× probes with protected grounds for isolated measurements.   
Recommended probes are the [[P5102]] and the [[P6113B]], both are 10× probes with protected grounds for isolated measurements.   
The [[P5102]] has the best isolation, allowing 600 V between reference ground and earth ground.
The [[P5102]] has the best isolation, allowing 600 V between reference ground and earth ground.
==Links==
* [https://www.eevblog.com/forum/testgear/tek-ths720a-portable-scope-teardowndiscussion// EEVBlog Forum thread on The THS7XXX series scopes]
* [https://www.youtube.com/watch?v=ajKtOf3kfuw Tektronix THS700 Series Oscilloscope Mega Video] by Near Far Media @ YouTube
{{Documents|Link=THS720}}
{{PatentLinks|THS720}}


==Internals==
==Internals==
Line 61: Line 73:
The DMM is a 3¾-digit Maxim MAX134CQH.
The DMM is a 3¾-digit Maxim MAX134CQH.


The analog scope section starts with an attenuator hybrid driven by four channels of
The analog scope section starts with an attenuator hybrid driven by four channels of HP (now Broadcom/Avago) optoisolators and NEC relays.   
HP (now Avago) optoisolators and NEC relays.  The hybrid contains the AC coupling
The hybrid contains the AC coupling capacitor and many laser trimmed resistors along with a custom Tek chip ([[165-2545-00]]) in a BGA package.
capacitor and many laser trimmed resistors along with a custom Tek [[165-2545-00]] BGA.
The signal then passes through a single-ended to differential transformer and goes to a custom-labeled Maxim two-channel high speed A/D converter ([[234-1503-20]]).
The signal then passes through a single-ended to differential transformer and
Note that the differential signal layout for channel 2 is not as good as channel 1 since one side of channel 2 goes through 2 vias not found on channel 1.
goes to a custom labeled Maxim two-channel high speed A/D converter [[234-1503-20]].
These optoisolators sometimes drift, causing a DC offset issue. They can be directly replaced with Broadcom/Avago part number HCNR201 (any of the -300E, -500E, -350E, or -550E variants will work) which are still readily available.
Note that the differential signal layout for channel 2 is not as good as channel 1
since one side of channel 2 goes through 2 vias not found on channel 1.


Firmware is updated using the [[067-1436-00|067-1436-00 Communication Pod]] with an adapter cable via an internal connector.
Firmware is updated using the [[067-1436-00|067-1436-00 Communication Pod]] with an adapter cable via an internal connector.


==Replacement Accessories==
A THS710A and THS720A can be upgraded to a THS720P with the removal of a few resistors on the main board (see pictures for details). No adjustment/calibration is required after this modification.
 
The DMM leads can be replaced with Mueller parts as used in the original lead kits 012-1482-00 for the standard set and ATLDX1 for the deluxe set as follows:
 
012-1482-00 DMM lead set contents (Mueller Electric part numbers):
* BU-4061-M-39-0 - UL Listed, Threaded Test Probe to Banana, Silicone - Black
* BU-4061-M-39-2 - UL Listed, Threaded Test Probe to Banana, Silicone - Red
* BU-60TBO - Steel Alligator Clip with #8-32 Threaded Barrel (Two needed)
* BU-62-0 - Insulator for BU-60 and BU-61 Series Clips - Black
* BU-62-2 - Insulator for BU-60 and BU-61 Series Clips - Red
* BU-00207-0 - Threaded Plunger Clip - Black
* BU-00207-2 - Threaded Plunger Clip - Red
 
ATLDX1 DMM lead set contents (Mueller Electric part numbers):
* BU-6161-M-39-0 - UL Listed, Test Lead Shrouded Banana Plugs Both ends Silicone - Black
* BU-6161-M-39-2 - UL Listed, Test Lead Shrouded Banana Plugs Both ends Silicone - Red
* BU-26101-0 - UL Listed, Test Probe Tip, Banana Plug Connection - Black
* BU-26101-2 - UL Listed, Test Probe Tip, Banana Plug Connection - Red
* BU-20431-0 - Right-angle Banana Jack, Hook Plunger - Black
* BU-20431-2 - Right-angle Banana Jack, Hook Plunger - Red
* BU-20433-0 - Flexible Rubber Coated Wire Grabber, Long - Black
* BU-20433-2 - Flexible Rubber Coated Wire Grabber, Long - Red
 
 
The cigarette lighter adapter is a standard 1.8m (6 foot) long cigarette lighter plug to 5.5mm x 2.1mm (Type A) center positive DC 'coaxial power connector' plug with red led and 1 A fuse.
 
 
The console cable and adapter, part numbers 012-1364-00 and 103-0403-00 can be replicated using an 8p8c RJ45 to female DB9 rewireable adapter and a 2 M long 8-conductor telephone type cable (wired pin 1 to 1, 2 to 2, etc) or Cat-5 Ethernet cable with a ferrite clipped near one end, sourced from ebay or the like.
 
The pinout for the adapter is as follows:
 
{| class="wikitable"
|-
! RJ45 !! Wire Color !! Function !! DB9 (female)
|-
| 1 || Brown || DCD- Data Carrier Detect || 7 - RTS
|-
| 2 || Blue || DSR- Data Set Ready || 4 - DTR
|-
| 3 || Yellow || DTR - Data Terminal Ready || 6 - DSR
|-
| 4 || Green || GND - Signal Ground || 5 - GND
|-
| 5 || Red || RXD - Receive Data || 3 - TXD
|-
| 6 || Black || TXD - Transmit Data || 2 - RXD
|-
| 7 || Orange || CTS - Clear To Send || 7 - RTS
|-
| 8 || Grey || RTS - Request To Send || 1&8 - DCD/CTS
|}
 


==Included Accessories==
NOTE: A THS710STD can be upgraded to a THS720STD, but due to main board differences, these models CANNOT be upgraded to a -A or -P model<br>
* P6113B - 10X, 100 MHz, CAT II, 300 V<sub>RMS</sub> Passive probes (THS710STD, THS720STD)
Additionally, lower model scopes cannot be upgraded to a THS730A due to different input hybrid modules being used in the THS730A to provide the increased bandwidth.
* P6117 - 10X, 200 MHz, CAT II, 300 V<sub>RMS</sub> Passive probes (THS730A, THS720A, THS710A)
* P5102 - 10X, 100 MHz, CAT II, 1000 V<sub>RMS</sub> Passive probes (THS720P)
* 012-1482-00 - Meter lead set
* THS7BAT - 4.8 V, 2.8 Ahr Ni-Cd Battery pack
* AC Power Adapter
** 119-4812-XX - North America
** 119-4813-XX - Universal European
** 119-4922-XX - United Kingdom
** 119-4923-XX - Japan
* 012-1364-00 - 2m RS-232 cable (8p8c RJ45 'console cable')
* 103-0403-00 - 9-pin adapter (8p8c RJ45 to DB-9 adapter)
* 016-1399-00 - Soft case
* 070-9247-XX - User manual (THS710STD, THS720STD)
* 070-9731-XX - User manual (THS730A, THS720P, THS720A, THS710A)
* 070-9257-XX - Reference manual (THS710STD, THS720STD)
* 070-9741-XX - Reference manual (THS730A, THS720P, THS720A, THS710A)
 
==Optional Accessories==
* P5102 - 10X, 100MHz, CAT II, 1000 V<sub>RMS</sub> Passive probes (THS730A, THS720A, THS710A, THS710STD, THS720STD)
* 012-1483-00 - Deluxe meter lead set (THS710STD, THS720STD)
* ATLDX1 - Deluxe meter lead set (THS730A, THS720P, THS720A, THS710A)
* THS7CHG - Battery charger
* THS7BAT - Extra 4.8 V, 2.8 Ahr Ni-Cd Battery pack
* 103-0090-00 - BNC to banana jack adapter to convert external trigger input to BNC (THS730A, THS720P, THS720A, THS710A)
* 174-1734-00 - Cigarette lighter adapter
* HC 411 - Thermal printer (006-7580-00 - Pack 5 paper rolls)
* THS7HCA - Hard carrying case
* A621 - BNC Current Probe, AC only, 2000 A max, 5Hz to 50 kHz
* A622 - BNC Current Probe, AC or DC, 100 A max, DC to 100 kHz
* A605 - DMM busbar-style current probe, AC only, 500A max, 48 Hz to 1 kHz, 1 mV/A
* A610 - DMM busbar-style current probe, AC or DC, 500A max, DC to 440 Hz, 1 mV/A
* P6129B - 1X-10X, 10 MHz/100 MHz Switchable passive probes
* P6561AS - 10X, 100 MHz SMD probes
* P6408 - Word Recogniser Trigger Probes - 16-bit word recogniser probe (trigger event recognition only)
* S60DWAV - DocuWave DOS software (THS710STD, THS720STD)
* WSTR31 - WaveStar software (THS730A, THS720P, THS720A, THS710A)
* 070-9245-XX - Programmer manual (THS710STD, THS720STD)
* 070-9751-XX - Programmer manual (THS730A, THS720P, THS720A, THS710A)
* 070-9246-XX - Service manual (THS710STD, THS720STD)
* 070-9752-XX - Service manual  (THS730A, THS720P, THS720A, THS710A)


==Software==
==Software==
Line 174: Line 93:
* [[Media:Docuwave_1.2.zip|Docuwave 1.2 for DOS]] (ZIP, 704 KB)
* [[Media:Docuwave_1.2.zip|Docuwave 1.2 for DOS]] (ZIP, 704 KB)
* [[Media:THS7XX_v1.3.zip|THS7XX HardCopy by Marco M. Schäck]] (ZIP, 63KB) [https://www.schaeck-online.de/download/?dir=THS7XX%20HardCopy www.schaeck-online.de]
* [[Media:THS7XX_v1.3.zip|THS7XX HardCopy by Marco M. Schäck]] (ZIP, 63KB) [https://www.schaeck-online.de/download/?dir=THS7XX%20HardCopy www.schaeck-online.de]
==Firmware==
* [[Media:THS720_v1.03_Firmware.zip|THS720STD v1.03 Firmware]] (ZIP)
* [[Media:THS710A_v1.11_Firmware.zip|THS710A v1.11 Firmware]] (ZIP)
* [[Media:THS720x_v1.16_Firmware.zip|THS720A, THS720P v1.16 Firmware]] (ZIP)


==Pictures==
==Pictures==
Line 203: Line 117:
Tek ths720a 7.jpg
Tek ths720a 7.jpg
Tek ths720a 8.jpg
Tek ths720a 8.jpg
Tektronix_THS720A_to_720P_Hack.jpg|THS720P Upgrade mod
</gallery>
</gallery>


Line 217: Line 132:
THS7CHG_Internal.jpg|Battery Charger Internal
THS7CHG_Internal.jpg|Battery Charger Internal
</gallery>
</gallery>
==Components==
{{Parts|THS720}}


[[Category:THS series scopes]]
[[Category:THS series scopes]]

Latest revision as of 04:46, 16 October 2024

Manuals – Specifications – Links – Pictures

The Tektronix THS720 is a portable 100 MHz, 500 MS/s (each channel) dual-channel digital oscilloscope with isolated inputs.

There were two variants, the THS720 STD and the THS720A. The primary difference is that the THS720A will trigger from the DMM input.

The THS720P includes features for electrical/power electronics measurements.

Murlan Kaufman designed the THS700 series high voltage isolated front end.

Key Specifications

  • please add

See THS720/Accessories for details on cables and other accessories.

Operation

Due to the isolated inputs, the probe ground must be connected even when compensating the probes with the "PROBE COMP" output. It can be used with any BNC probe but the scale factor pin found on many Tektronix probes is not used. The vertical menu has a scale factor entry (1×, 10×, 100×, 1000×) which can also be used for direct BNC inputs.

Recommended probes are the P5102 and the P6113B, both are 10× probes with protected grounds for isolated measurements. The P5102 has the best isolation, allowing 600 V between reference ground and earth ground.

Links

Documents Referencing THS720

(no results)

Internals

Primary microprocessor is the Motorola/Freescale MC68331CFC16. An Intel E28F008SA120 Flash Memory chip is used for setup, cal and waveform storage. The switching power supply is run by a TL1451A, a TI two channel boost/buck controller. The DMM is a 3¾-digit Maxim MAX134CQH.

The analog scope section starts with an attenuator hybrid driven by four channels of HP (now Broadcom/Avago) optoisolators and NEC relays. The hybrid contains the AC coupling capacitor and many laser trimmed resistors along with a custom Tek chip (165-2545-00) in a BGA package. The signal then passes through a single-ended to differential transformer and goes to a custom-labeled Maxim two-channel high speed A/D converter (234-1503-20). Note that the differential signal layout for channel 2 is not as good as channel 1 since one side of channel 2 goes through 2 vias not found on channel 1. These optoisolators sometimes drift, causing a DC offset issue. They can be directly replaced with Broadcom/Avago part number HCNR201 (any of the -300E, -500E, -350E, or -550E variants will work) which are still readily available.

Firmware is updated using the 067-1436-00 Communication Pod with an adapter cable via an internal connector.

A THS710A and THS720A can be upgraded to a THS720P with the removal of a few resistors on the main board (see pictures for details). No adjustment/calibration is required after this modification.

NOTE: A THS710STD can be upgraded to a THS720STD, but due to main board differences, these models CANNOT be upgraded to a -A or -P model
Additionally, lower model scopes cannot be upgraded to a THS730A due to different input hybrid modules being used in the THS730A to provide the increased bandwidth.

Software

Pictures

THS720

THS720A

THS720P

Accessories

Components

Some Parts Used in the THS720

Part Part Number(s) Class Description Used in
Motorola 68000 156-1445-00 Monolithic integrated circuit 16-bit microprocessor 4041 AM700 DAS9200 Keithley 182 RTD710 SG5030 Prism 3002 THS720