1A4: Difference between revisions
(test for improved template) |
(chapters) |
||
Line 13: | Line 13: | ||
The '''Tektronix Type 1A4''' is a 1-series vertical plug-in for [[Main_Page#500_Series|500-series scopes]]. | The '''Tektronix Type 1A4''' is a 1-series vertical plug-in for [[Main_Page#500_Series|500-series scopes]]. | ||
It has four input channels and 50 MHz bandwidth. | It has four input channels and 50 MHz bandwidth. | ||
Type 1A4 was [[introduced in 1967]] and lasted until the end | |||
of the [[Main_Page#500_Series|500-series line]] in 1974. | |||
The four channels are grouped into two groups of two channels. | The four channels are grouped into two groups of two channels. | ||
Line 21: | Line 24: | ||
This allows high-speed and low-speed signals to be displayed together, | This allows high-speed and low-speed signals to be displayed together, | ||
similar to what a dual-beam scope can do, but without some of the cost and complexity. | similar to what a dual-beam scope can do, but without some of the cost and complexity. | ||
Like the Type [[1A2]] and unlike the Type [[1A1]], | |||
the Type 1A4 has a Trigger Output selector that controls | |||
which channel provides triggering when the mainframe trigger is in Plug-In mode. | |||
==Specifications== | |||
[[Category:Specifications needed]] ''please add'' | |||
Maximum channel sensitivity is 10 mV/div, | Maximum channel sensitivity is 10 mV/div, | ||
Line 26: | Line 36: | ||
for approximately 200 μV/div AC with about 20 Hz - 1 MHz bandwidth. | for approximately 200 μV/div AC with about 20 Hz - 1 MHz bandwidth. | ||
==Internals== | |||
The signal path of each channel of the 1A4 is as follows. | The signal path of each channel of the 1A4 is as follows. | ||
First the signal passes through the attenuators. | First the signal passes through the attenuators. | ||
Line 41: | Line 48: | ||
After the multiplexer network, the signal passes through a common base amplifier | After the multiplexer network, the signal passes through a common base amplifier | ||
followed by [[6DJ8]] tube operating in common grid configuration. | followed by [[6DJ8]] tube operating in common grid configuration. | ||
==Pictures== | ==Pictures== |
Revision as of 04:49, 6 October 2014
Template:Plugin Sidebar 2 The Tektronix Type 1A4 is a 1-series vertical plug-in for 500-series scopes. It has four input channels and 50 MHz bandwidth.
Type 1A4 was introduced in 1967 and lasted until the end of the 500-series line in 1974.
The four channels are grouped into two groups of two channels. Type 1A4 has a special "trace slaving" mode which, when used in a 547 mainframe, allows channels 1 and 2 to be displayed using the A time base, and channels 3 and 4 to be displayed with the B time base. This allows high-speed and low-speed signals to be displayed together, similar to what a dual-beam scope can do, but without some of the cost and complexity.
Like the Type 1A2 and unlike the Type 1A1, the Type 1A4 has a Trigger Output selector that controls which channel provides triggering when the mainframe trigger is in Plug-In mode.
Specifications
please add
Maximum channel sensitivity is 10 mV/div, but a Signal Out jack makes it possible to cascade two channels for approximately 200 μV/div AC with about 20 Hz - 1 MHz bandwidth.
Internals
The signal path of each channel of the 1A4 is as follows. First the signal passes through the attenuators. Then it is clamped by two diodes and applied to the the gate of a JFET source follower. The source of the source follower is the trigger pickoff point. From there the vertical signal path goes through an NPN emitter follower followed by an NPN differential amplifier, at which point the signal becomes differential. Next, the signal passes through an analog multiplexer made with 1N4152 silicon switching diodes. After the multiplexer network, the signal passes through a common base amplifier followed by 6DJ8 tube operating in common grid configuration.