262: Difference between revisions
No edit summary |
(on limited demand list in 1971 catalog) |
||
Line 1: | Line 1: | ||
The Tektronix 262 is a programmer for the Tektronix [[6R1]] and [[6R1A]] digital plug-ins for the [[567]] [[sampling oscilloscope]]. | The '''Tektronix 262''' is a programmer for the Tektronix [[6R1]] and [[6R1A]] digital plug-ins for the [[567]] [[sampling oscilloscope]]. | ||
It connects via a cable to J34 on the 6R1 or 6R1A. | |||
Small printed circuit boards called program cards fit into slots in a bus inside the 262. | It connects via a cable to J34 on the 6R1 or 6R1A. Small printed circuit boards called program cards fit into slots in a bus inside the 262. Each of these cards specifies one measurement. | ||
Each of these cards specifies one measurement. | |||
These program cards are configurable by the user. | These program cards are configurable by the user. | ||
The 262 has slots for up to eight program cards. | |||
They are activated one at a time, either | The 262 has slots for up to eight program cards. They are activated one at a time, either | ||
manually by pressing program selection switches on the front panel of the 262, | manually by pressing program selection switches on the front panel of the 262, | ||
or by having the 262 execute the measurements automatically in sequence, | or by having the 262 execute the measurements automatically in sequence, | ||
or the measurements can be activated remotely when the 262 is slaved to another 262. | or the measurements can be activated remotely when the 262 is slaved to another 262. | ||
The 262 was discontinued after 1971. | |||
* [http://bama.edebris.com/download/tek/262/Tek%20262.pdf Tektronix 262 Manual (PDF)] | * [http://bama.edebris.com/download/tek/262/Tek%20262.pdf Tektronix 262 Manual (PDF)] |
Revision as of 10:15, 10 June 2016
The Tektronix 262 is a programmer for the Tektronix 6R1 and 6R1A digital plug-ins for the 567 sampling oscilloscope.
It connects via a cable to J34 on the 6R1 or 6R1A. Small printed circuit boards called program cards fit into slots in a bus inside the 262. Each of these cards specifies one measurement. These program cards are configurable by the user.
The 262 has slots for up to eight program cards. They are activated one at a time, either manually by pressing program selection switches on the front panel of the 262, or by having the 262 execute the measurements automatically in sequence, or the measurements can be activated remotely when the 262 is slaved to another 262.
The 262 was discontinued after 1971.
-
Front view
-
Rear view
-
Inside view