7D01: Difference between revisions
No edit summary |
No edit summary |
||
Line 19: | Line 19: | ||
* 8 channels at 508 bits/channel, maximum external clock period 20ns (50MHz) | * 8 channels at 508 bits/channel, maximum external clock period 20ns (50MHz) | ||
* 16 channels at 254 bits/channel, maximum external clock period 40ns (25MHz) | * 16 channels at 254 bits/channel, maximum external clock period 40ns (25MHz) | ||
}} | }} | ||
{{Spec | Sampling Rate | 10 ns to 5 ms per sample (1—2—5) or external clock up to 50 MHz}} | {{Spec | Sampling Rate | 10 ns to 5 ms per sample (1—2—5) or external clock up to 50 MHz}} | ||
Line 33: | Line 29: | ||
{{EndSpecs}} | {{EndSpecs}} | ||
[[Category:Specifications needed]] ''please add'' | [[Category:Specifications needed]] ''please add'' | ||
==Notes== | |||
'''Note about external clock rates''' (from Jim Mauck): | |||
''When I was a Tek Service Technician I worked on the 7D01. For several years I tested every 7D01 I worked on (and that was a lot of them) with a 100MHz external clock in 16 channel mode. I would use a DF2 and set it to reacquire continuously as long as the 7D01 memory was the same as the original data I stored into the DF2 memory. The analyzer would run for hours without error. The funny part is that it wasn't until I had been doing this for several years that I realized it wasn't specified to run at that frequency. I continued to test them that way even after I discovered my error. However the instrument exceeding the specifications might be due to the data source providing a generous setup and hold time relative to the active clock edge.'' | |||
==Links== | ==Links== |
Revision as of 07:11, 10 September 2016
Template:Plugin Sidebar 2 The Tektronix 7D01 is a logic analyzer plug-in for the 7000-series scopes. Compatible extension modules include the DF1 and DF2 display formatters and the DL2 latch (glitch detector).
Key Specifications
Channels |
|
---|---|
Sampling Rate | 10 ns to 5 ms per sample (1—2—5) or external clock up to 50 MHz |
Trigger Sources |
|
please add
Notes
Note about external clock rates (from Jim Mauck):
When I was a Tek Service Technician I worked on the 7D01. For several years I tested every 7D01 I worked on (and that was a lot of them) with a 100MHz external clock in 16 channel mode. I would use a DF2 and set it to reacquire continuously as long as the 7D01 memory was the same as the original data I stored into the DF2 memory. The analyzer would run for hours without error. The funny part is that it wasn't until I had been doing this for several years that I realized it wasn't specified to run at that frequency. I continued to test them that way even after I discovered my error. However the instrument exceeding the specifications might be due to the data source providing a generous setup and hold time relative to the active clock edge.