543: Difference between revisions
No edit summary |
No edit summary |
||
Line 17: | Line 17: | ||
While the 545 has two non-calibrated X-input sensitivities, the 543 has | While the 545 has two non-calibrated X-input sensitivities, the 543 has | ||
an X-input with three calibrated selectable deflection sensitivities: 0.1 V/cm, 1 V/cm, and | an X-input with three calibrated selectable deflection sensitivities: 0.1 V/cm, 1 V/cm, and 10 V/cm. | ||
10 V/cm. | |||
The standard CRT for the 543 is the [[T65]] with P2 [[phosphor]], part number 154-175. | The standard CRT for the 543 is the [[T65]] with P2 [[phosphor]], part number 154-175. | ||
The standard CRT for the 543B is part number [[154-0478-00]], also known as the T5470-31-2. | The standard CRT for the 543B is part number [[154-0478-00]], also known as the T5470-31-2. | ||
The total acceleration voltage on the CRT is 10 kV. | The total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five [[5642]] HV tube diodes. | ||
The CRT power supply uses five [[5642]] HV tube diodes. | |||
543B is a hybrid | The '''543B''' is a tube/transistor hybrid scope. The vertical amplifier has a [[6DJ8]] cathode follower stage followed by two transistor/tube cascode stages with a 186 Ω [[delay line]] inbetween. | ||
==Specifications== | ==Specifications== |
Revision as of 23:15, 17 May 2017
The Tektronix Type 543 (rack mount RM43) is an all-tube 30 MHz scope introduced in 1958. It takes letter-series and 1-series plug-ins. It is similar to a 545, but without the second, delayed timebase. Instead, it has a range of horizontal magnifiers from ×2 to ×100. It has the same six-stage balanced distributed amplifier (twelve 6DK6 tubes) as the 545.
While the 545 has two non-calibrated X-input sensitivities, the 543 has an X-input with three calibrated selectable deflection sensitivities: 0.1 V/cm, 1 V/cm, and 10 V/cm.
The standard CRT for the 543 is the T65 with P2 phosphor, part number 154-175. The standard CRT for the 543B is part number 154-0478-00, also known as the T5470-31-2.
The total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five 5642 HV tube diodes.
The 543B is a tube/transistor hybrid scope. The vertical amplifier has a 6DJ8 cathode follower stage followed by two transistor/tube cascode stages with a 186 Ω delay line inbetween.
Specifications
please add
Pictures
-
543
-
543B with CA
-
543
-
543
-
543
-
543
-
543
-
RM543B
-
RM543B side
-
543B
-
543B
-
543 Block Diagram
-
543 Horizontal Amplifier
-
543 Vertical Amplifier
-
543 Trigger
-
543 Timebase
-
543 Delay Line
-
543 CRT Circuit
-
543 Low-Voltage Power Supply
-
543 Calibrator