7A14: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 13: Line 13:
The '''Tektronix 7A14''' is a 120 MHz current probe amplifier vertical plug-in for [[7000-series scopes]].   
The '''Tektronix 7A14''' is a 120 MHz current probe amplifier vertical plug-in for [[7000-series scopes]].   
It is intended for current probes [[P6021]] and [[P6022]].
It is intended for current probes [[P6021]] and [[P6022]].
In the 7A14, the ring around the input [[BNC connector]] that is used to identify ×10/×100 probes on voltage probes serves the purpose of detecting the difference between the P6021 and P6022 probes, and switching in appropriate termination and gain.  The P6021 shorts this ring to ground.


==Specifications==
==Specifications==
Line 23: Line 25:


* [http://www.barrytech.com/tektronix/tek7000/tek7a14.html Tek 7A14 @ barrytech.com]
* [http://www.barrytech.com/tektronix/tek7000/tek7a14.html Tek 7A14 @ barrytech.com]
==Internals==
The 7A14 uses twelve Tek-made [[miniature relays]] that can be a service issue.


==Pictures==
==Pictures==

Revision as of 07:28, 9 January 2018

Template:Plugin Sidebar 2

The Tektronix 7A14 is a 120 MHz current probe amplifier vertical plug-in for 7000-series scopes. It is intended for current probes P6021 and P6022.

In the 7A14, the ring around the input BNC connector that is used to identify ×10/×100 probes on voltage probes serves the purpose of detecting the difference between the P6021 and P6022 probes, and switching in appropriate termination and gain. The P6021 shorts this ring to ground.

Specifications

  • Bandwidth: 25 Hz – 50 MHz (P6021 Probe)
  • Bandwidth: 250 Hz – 105 MHz (P6022 Probe)
  • Ranges: 1 mA/Div to 1 A/Div in 1–2–5 sequence

Links

Internals

The 7A14 uses twelve Tek-made miniature relays that can be a service issue.

Pictures