5B25N: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
m (→top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=5000-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=5000-series scopes → designers=) |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | | ||
manufacturer=Tektronix |series=5000-series scopes |type= 5B25N | | |||
summary=20 MHz digitizer time base | | summary=20 MHz digitizer time base | | ||
image=Tek-5b25-front-crop.jpg | | image=Tek-5b25-front-crop.jpg | | ||
caption=Tektronix 5B25N front | | caption=Tektronix 5B25N front | | ||
designers= | | |||
introduced=1981 | | introduced=1981 | | ||
discontinued=1988 | | discontinued=1988 | | ||
Line 12: | Line 12: | ||
[[Category:Manual needed]] | [[Category:Manual needed]] | ||
}} | }} | ||
The '''Tektronix 5B25N''' is a "digitizer time base" for the [[5223]] scope, i.e. a time base that also contains a sample clock generator. | The '''Tektronix 5B25N''' is a "digitizer time base" for the [[5223]] scope, i.e. a time base that also contains a sample clock generator. | ||
It will also operate in 5400-series mainframes as a generic time base. | It will also operate in 5400-series mainframes as a generic time base. |
Revision as of 01:02, 14 August 2021
The Tektronix 5B25N is a "digitizer time base" for the 5223 scope, i.e. a time base that also contains a sample clock generator. It will also operate in 5400-series mainframes as a generic time base. The 5B25N/5223 system uses real-time sampling at sweep rates of 0.1 ms/div or slower. At sweep rates of 50 us/div or faster, equivalent-time sampling is used. The 5B25N uses the 155-0109-01 trigger chip (U95).
Key Specifications
Sweep | 200 ns/Div to 5 s/Div, 1—2—5 |
---|---|
Triggering | > 0.4 Div or 50 mV to 1 MHz, > 0.6 Div or 200 mV to 20 MHz |
X-Y mode | 50 mV/Div, 180 ns rise time, 2 MHz bandwidth, 1 MΩ // 24 pF input |
Features |
|