A6303: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 29: | Line 29: | ||
Tek A6363 max current rating.jpg | A6303 maximum current vs frequency | Tek A6363 max current rating.jpg | A6303 maximum current vs frequency | ||
Tek A6363 insertion impedance.jpg | A6303 insertion impedance vs frequency | Tek A6363 insertion impedance.jpg | A6303 insertion impedance vs frequency | ||
</gallery> | |||
=== Unusual Transparent A6303 === | |||
<gallery> | |||
Tek a6303 clear 1.jpg | |||
Tek a6303 clear 2.jpg | |||
Tek a6303 clear 3.jpg | |||
Tek a6303 clear 4.jpg | |||
Tek a6303 clear 5.jpg | |||
Tek a6303 clear 6.jpg | |||
Tek a6303 clear 7.png | |||
Tek a6303 clear 8.png | |||
Tek a6303 clear 9.png | |||
Tek a6303 clear 10.png | |||
Tek a6303 clear 11.png | |||
</gallery> | </gallery> | ||
[[Category:Oscilloscope current probes]] | [[Category:Oscilloscope current probes]] | ||
[[Category:Introduced in 1978]] | [[Category:Introduced in 1978]] |
Revision as of 23:12, 2 February 2021
The Tektronix A6303 aka P6303 is a 15 MHz, 100 A current probe. It requires an AM503, AM5030 or 11A16 amplifier for operation. The Tektronix 067-0865-00 is a calibration fixture for the P6303.
Key Specifications
Bandwidth | DC − 15 MHz |
---|---|
Rise time | ≤23 ns |
Input range | 100 A continuous, 500 A peak, ≤10 kA · μs (with 11A16: 52.5 A continuous)
Derating: 200 Ap-p up to 20 kHz, down to 20 Ap-p at 20 MHz (see curve) |
Sensitivity | 10 mA/Div to 50 A/Div, 1−2−5 (with AM503) |
Noise | ≤3 mA (@ 100 MHz amplifier BW, 10 mA range, DC) |
Manuals
Links
- 120-1102-00 Current Transformer
- http://www.tek.com/datasheet/current-measurement-system-probes
- Tek A6303 @ barrytech.com
Pictures
-
P6303 probe
-
Open jaws
-
A6303 maximum current vs frequency
-
A6303 insertion impedance vs frequency