P6055: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(added specs and subcategory)
No edit summary
Line 1: Line 1:
[[File:P6055 1.jpg | thumb | 350px | right]]
{{Probe Sidebar
[[File:P6055 2.jpg | thumb | 350px | right]]
|manufacturer=Tektronix
|model=P6055
|summary=
|image=P6055 1.jpg  
|caption=Tektronix P6055
|for=1 MΩ scope inputs
|introduced=1971
|discontinued=(?)
|manuals=
* [http://w140.com/P6055.pdf Tektronix P6055 Manual (PDF)]
* [http://w140.com/tek_p6055_1971_cat.pdf Tektronix P6055 Description in 1971 Catalog (PDF)]
}}
[[File:P6055 2.jpg | thumb | 250px | right]]
The '''Tektronix P6055''' is a 10× probe pair for differential amplifiers such as e.g. the [[7A13]] having 1 MΩ Inputs and 20 to 47 pF input capacity.
The '''Tektronix P6055''' is a 10× probe pair for differential amplifiers such as e.g. the [[7A13]] having 1 MΩ Inputs and 20 to 47 pF input capacity.
The probe's resistive attenuation ratio is adjustable to an exact ×10 for the given amplifier input.
The probe's resistive attenuation ratio is adjustable to an exact ×10 for the given amplifier input.
Line 18: Line 30:
{{EndSpecs}}
{{EndSpecs}}


==Manuals==
* [http://w140.com/P6055.pdf Tektronix P6055 Manual (PDF)]
* [http://w140.com/tek_p6055_1971_cat.pdf Tektronix P6055 Description in 1971 Catalog (PDF)]
 
[[Category:Introduced in 1971]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:Passive Differential probes]]
[[Category:Passive Differential probes]]

Revision as of 09:08, 19 August 2021

Tektronix P6055
Tektronix P6055

Compatible with 1 MΩ scope inputs

Produced from 1971 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6055 is a 10× probe pair for differential amplifiers such as e.g. the 7A13 having 1 MΩ Inputs and 20 to 47 pF input capacity. The probe's resistive attenuation ratio is adjustable to an exact ×10 for the given amplifier input. This allows precise gain matching to improve CMRR.

Tektronix also recommended the P6055 for the 7D12/M2 sample/hold, because of the trimming feature improving the accuracy of voltage readings.

The P6055 has a readout pin.

Key Specifications

Compensation Range 1 MΩ//12-47 pF
Attenuation Adjustable to ×10
Input Impedance 1 MΩ / 10-12.5 pF
Step Response < 4ns
CMRR with 7A13 or 1A5 20,000:1 from DC - 1kHz, 100:1 at 20 MHz
Max. input ±500 V Maximum Common Mode Voltage