T: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
Line 12: Line 12:
* [[Media:tek_type_t_fcp.pdf|Tektronix Type T Factory Calibration Procedure (PDF, OCR)]]
* [[Media:tek_type_t_fcp.pdf|Tektronix Type T Factory Calibration Procedure (PDF, OCR)]]
* [[Media:Tek type t mod 104.pdf|Tektronix Type T Mod 104 (PDF, needs OCR)]]
* [[Media:Tek type t mod 104.pdf|Tektronix Type T Mod 104 (PDF, needs OCR)]]
* [[Media:Tek type t cal outline.pdf|Tektronix Type T Calibration Outline (PDF, OCR)]]
}}
}}
The '''Tektronix Type T''' is a timebase plug-in primarily intended for use in the [[536|model 536 X-Y scope]].
The '''Tektronix Type T''' is a timebase plug-in primarily intended for use in the [[536|model 536 X-Y scope]].

Revision as of 10:12, 5 May 2021

Template:Plugin Sidebar 2 The Tektronix Type T is a timebase plug-in primarily intended for use in the model 536 X-Y scope. It contains trigger and sweep circuitry. The typical use of a Type T plug-in is as the X-axis plug-in in a 536, to make the 536 behave like a normal oscilloscope instead of an X-Y scope. However, there is no capability for internal triggering – a jumper must be connected from the Vertical Signal Out on the 536 to the External Trig on the Type T.

Plugging a Type T into a vertical slot of a normal 500-series scope produces a raster, and using the scope's Z-axis input this allows a crude video display.

The banana jack on the back of the plugin is to provide retrace blanking when used in the horizontal slot of a 536.

The Type T was introduced in 1957 and dropped after 1972, the same as its primary host, the 536. (Types K, L, and T are tied for longest production life, at 16 years, B, D, and G are next at 15 years.)

Pictures