7A19: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 14: Line 14:
}}
}}
The '''Tektronix 7A19''' is a one-channel 600 MHz vertical amplifier plug-in for [[7000-series scopes]], designed by [[Thor Hallen]] and introduced along with the [[7904]] mainframe in late 1971/early 1972 (note 1).
The '''Tektronix 7A19''' is a one-channel 600 MHz vertical amplifier plug-in for [[7000-series scopes]], designed by [[Thor Hallen]] and introduced along with the [[7904]] mainframe in late 1971/early 1972 (note 1).
==Operation==
The 7A19 has no variable gain control.  An option (#4) was available that added a variable signal delay (±0.5 ns implemented using a mechanically variable passive delay line), intended to match timing between multiple channels.
The pre-charge setting on the input coupling switch is intended for situations where there might be residual charge on the input coupling capacitor that could overload the input.  To use it, one sets the switch to PRE-CHG before connecting the input signal, then waits two seconds before switching to AC (LF point is 1 kHz).  The PRE-CHG setting also serves as a ×100 attenuator having a 5 kΩ input impedance in series with 2 μF, extending LF cutoff down to 20 Hz. In the AC GND position, the input is disconnected from the amplifier and terminated in a capacitively coupled 50 Ω load.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Input impedance | 50 Ω  }}
{{Spec | Bandwidth | 600 MHz (500 MHz in [[7904]]) }}
{{Spec | Bandwidth | 600 MHz (500 MHz in [[7904]]) }}
{{Spec | Deflection | 10 mV/Div to 1 V/Div, 1−2−5. Pre-charge circuit may be used as a calibrated ×100 attenuator. }}
{{Spec | Deflection | 10 mV/Div to 1 V/Div, 1−2−5. Pre-charge circuit may be used as a calibrated ×100 attenuator. }}
{{Spec | Maximum input | 2 W average or 50 Div, in AC mode 100 V DC+peak AC }}
{{Spec | Maximum input | 2 W average or 50 Div, in AC mode 100 V DC+peak AC }}
{{Spec | Input impedance | 50 Ω  }}
{{Spec | Variable delay (Opt.4) | −0.5 ns to +0.5 ns}}
{{Spec | Variable delay (Opt.4) | −0.5 ns to +0.5 ns}}
{{EndSpecs}}
{{EndSpecs}}
==Operation==
The 7A19 has no variable gain control.  An option (#4) was available that added a variable signal delay (±0.5 ns implemented using a mechanically variable passive delay line), intended to match timing between multiple channels.
The pre-charge setting on the input coupling switch is intended for situations where there might be residual charge on the input coupling capacitor that could overload the input.  To use it, one sets the switch to PRE-CHG before connecting the input signal, then waits two seconds before switching to AC (LF point is 1 kHz).  The PRE-CHG setting also serves as a ×100 attenuator having a 5 kΩ input impedance in series with 2 μF, extending LF cutoff down to 20 Hz. In the AC GND position, the input is disconnected from the amplifier and terminated in a capacitively coupled 50 Ω load.


==Internals==
==Internals==

Revision as of 10:40, 12 May 2023

Tektronix 7A19
600 MHz amplifier
7A19 front view

Compatible with 7000-series scopes

Produced from 1971 to 1991

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 7A19 is a one-channel 600 MHz vertical amplifier plug-in for 7000-series scopes, designed by Thor Hallen and introduced along with the 7904 mainframe in late 1971/early 1972 (note 1).

Key Specifications

Bandwidth 600 MHz (500 MHz in 7904)
Deflection 10 mV/Div to 1 V/Div, 1−2−5. Pre-charge circuit may be used as a calibrated ×100 attenuator.
Maximum input 2 W average or 50 Div, in AC mode 100 V DC+peak AC
Input impedance 50 Ω
Variable delay (Opt.4) −0.5 ns to +0.5 ns

Operation

The 7A19 has no variable gain control. An option (#4) was available that added a variable signal delay (±0.5 ns implemented using a mechanically variable passive delay line), intended to match timing between multiple channels.

The pre-charge setting on the input coupling switch is intended for situations where there might be residual charge on the input coupling capacitor that could overload the input. To use it, one sets the switch to PRE-CHG before connecting the input signal, then waits two seconds before switching to AC (LF point is 1 kHz). The PRE-CHG setting also serves as a ×100 attenuator having a 5 kΩ input impedance in series with 2 μF, extending LF cutoff down to 20 Hz. In the AC GND position, the input is disconnected from the amplifier and terminated in a capacitively coupled 50 Ω load.

Internals

The 50 Ω input impedance of the 7A19 is provided by a pair of 100 Ω resistors in parallel. The resistors are protected by a pair of fuses in parallel. The manual explains that the motivation for using two fuses in parallel is to minimize the effect of the series impedance of the fuses. The fuse part number in the manual (Littelfuse 279-100) appears to be wrong since the MICRO 279 series fuse has 25.4 mm long pins. The correct replacement fuse is Littelfuse 273-100 which comes in a box of 5 labeled "MICRO 1/10A 273", it has 4.32 mm long pins.

The only active device in the vertical signal path of the 7A19 is an 155-0068-00 amplifier hybrid, (U40, Tek internal part number H101). A second 155-0068-00 is used in the trigger signal path of the 7A19, which is almost identical to the vertical signal path.

The 7A19 uses the ±50 V supplies provided by the mainframe.

Notes

  1. See 7A11 and John Addis, Good Engineering and Fast Vertical Amplifiers, in Jim Williams (Ed.), Analog Circuit Design: Art, Science and Personalities (1991), p. 114, and Tektronix New Products 1972 brochure.

Prices

Year 1972 1977 1980 1984 1987 1990
Catalog price $500 $1,000 $1,475 $2,450 $2,895 $3,340
In 2021 Dollars $3,300 $4,600 $5,000 $6,500 $7,000 $7,100

Pictures

==

Pictures

Earlier model

Later model (B030000+)

Custom ICs used in the 7A19

Page Model Part nos Description Designers Used in
155-0068-00 H101 155-0068-00 amplifier 7A19