DM501A: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 8: | Line 8: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | DC Voltage | 200 mV<sub>DC</sub> to 200 V<sub>DC</sub> in decade ranges | {{Spec | DC Voltage | 200 mV<sub>DC</sub> to 200 V<sub>DC</sub> in decade ranges, and 1000 V<sub>DC</sub>; Input resistance 10 MΩ, CMRR >100 dB at DC, 80 dB at 50 and 60 Hz (1 kΩ unbal.), NMRR 60 dB at 50 or 60 Hz }} | ||
{{Spec | AC Voltage | 200 mV<sub>DC</sub> to 200 V<sub>AC</sub> in decade ranges, and 500 V<sub>AC</sub> (0.6% + 0.05% (500 V:0.2%) FS | {{Spec | DC Voltage accuracy | 0.05% + 0.01% (200 mV: 0.015% / 1000 V: 0.02%) FS }} | ||
{{Spec | DC Current | 200 μA to 2 A in decade ranges | {{Spec | AC Voltage | 200 mV<sub>DC</sub> to 200 V<sub>AC</sub> in decade ranges, and 500 V<sub>AC</sub>; Input impedance 10 MΩ // ≤160 pF, CMRR 60 dB at 50 or 60 Hz (1 kΩ unbal.)}} | ||
{{Spec | AC Current | 200 μA to 2 A in decade ranges | {{Spec | AC Voltage accuracy | 0.6% + 0.05% (500 V: 0.2%) FS; True RMS; }} | ||
{{Spec | Ohms | 200 Ω to 20 MΩ in decade range; current 1 mA, 1 mA, 100 μA – 0.1 μA respectively | {{Spec | DC Current | 200 μA to 2 A in decade ranges}} | ||
{{Spec | Temperature | –62°C to +150°C | {{Spec | DC Current accuracy | 0.2% + 0.015% FS }} | ||
{{Spec | AC Current | 200 μA to 2 A in decade ranges}} | |||
{{Spec | AC Current accuracy | 0.6% + 0.05% FS (for 20 Hz to 10 kHz sine >5% FS) }} | |||
{{Spec | Ohms | 200 Ω to 20 MΩ in decade range; current 1 mA, 1 mA, 100 μA – 0.1 μA respectively}} | |||
{{Spec | Ohms accuracy | 0.15% (20 MΩ: 0.5%) + 0.015% FS }} | |||
{{Spec | Temperature | –62°C to +240°C (+0/-6°C or +2/-8°C any probe, uncal.) }} | |||
{{Spec | Temperature accuracy | +150°C, ±2°C cal. probe, ±4°C uncal. probe; +150°C to +240°C, +0/-6°C or +2/-8°C any probe, uncal. }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
Revision as of 01:42, 14 September 2023
The Tektronix DM501A is a 4½ digit True RMS multimeter plug-in for the TM500 system.
It replaced the DM501 (which suffered from accuracy limitations) in 1980. It also has a temperature input, requiring the P6601 PT-100 probe with a 2-pin LEMO S-series connector.
Key Specifications
DC Voltage | 200 mVDC to 200 VDC in decade ranges, and 1000 VDC; Input resistance 10 MΩ, CMRR >100 dB at DC, 80 dB at 50 and 60 Hz (1 kΩ unbal.), NMRR 60 dB at 50 or 60 Hz |
---|---|
DC Voltage accuracy | 0.05% + 0.01% (200 mV: 0.015% / 1000 V: 0.02%) FS |
AC Voltage | 200 mVDC to 200 VAC in decade ranges, and 500 VAC; Input impedance 10 MΩ // ≤160 pF, CMRR 60 dB at 50 or 60 Hz (1 kΩ unbal.) |
AC Voltage accuracy | 0.6% + 0.05% (500 V: 0.2%) FS; True RMS; |
DC Current | 200 μA to 2 A in decade ranges |
DC Current accuracy | 0.2% + 0.015% FS |
AC Current | 200 μA to 2 A in decade ranges |
AC Current accuracy | 0.6% + 0.05% FS (for 20 Hz to 10 kHz sine >5% FS) |
Ohms | 200 Ω to 20 MΩ in decade range; current 1 mA, 1 mA, 100 μA – 0.1 μA respectively |
Ohms accuracy | 0.15% (20 MΩ: 0.5%) + 0.015% FS |
Temperature | –62°C to +240°C (+0/-6°C or +2/-8°C any probe, uncal.) |
Temperature accuracy | +150°C, ±2°C cal. probe, ±4°C uncal. probe; +150°C to +240°C, +0/-6°C or +2/-8°C any probe, uncal. |
Rear interface
The DM501A has a rear input, selectable by a front-panel button, on B28 (Hi) / A29 (Lo). Unlike the DM501 (non-A), it has no digital outputs. Input voltage on the rear interface is limited to 200 V peak / 100 V RMS.
Pictures
-
DM501A
-
DM501A
-
DM501A Option 2 (no temperature range) on an extension cable
-
DM501A
-
DM501A rear connector
-
DM501A RHS
-
DM501A LHS
-
DM501A LHS, shielding removed
Parts
Some Parts Used in the DM501A
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
AD536 | 156-1259-00 | Monolithic integrated circuit | RMS/DC converter | DM501A • DM502A • DM5010 • Keithley 177 • Keithley 179 • Keithley 195A |
Siliconix LD120 | 156-1306-00 | Monolithic integrated circuit | 4½ digit integrating ADC (analog section) | DM501A • DM5010 |
Siliconix LD121A | 156-1305-00 | Monolithic integrated circuit | 4½ digit integrating ADC (digital section) | 7A13 • DM501A |