5B40: Difference between revisions
Jump to navigation
Jump to search
(year) |
No edit summary |
||
Line 11: | Line 11: | ||
}} | }} | ||
The '''Tektronix 5B40''' is a 60 MHz timebase for [[5000-series scopes]], particularly the 5400-series. | The '''Tektronix 5B40''' is a 60 MHz timebase for [[5000-series scopes]], particularly the 5400-series. | ||
The trigger signal passes through source switching, coupling switching, and then a JFET source-follower buffer. | |||
Next, the signal is buffered by a PNP emitter-follower biased at around 5mA collector current. | |||
That provides a known (low) source impedance for driving the switch-selectable LF reject and HF reject filters. | |||
The output of the filters drives a discrete NPN differential amplifier, which drives U165, a [[151-0109-01]] Tek-made trigger IC. | |||
==Specifications== | ==Specifications== |
Revision as of 14:50, 7 December 2014
Template:Plugin Sidebar 2 The Tektronix 5B40 is a 60 MHz timebase for 5000-series scopes, particularly the 5400-series. The trigger signal passes through source switching, coupling switching, and then a JFET source-follower buffer. Next, the signal is buffered by a PNP emitter-follower biased at around 5mA collector current. That provides a known (low) source impedance for driving the switch-selectable LF reject and HF reject filters. The output of the filters drives a discrete NPN differential amplifier, which drives U165, a 151-0109-01 Tek-made trigger IC.
Specifications
please add