{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Parallel inputs | | {{Spec | Parallel inputs | Eight data channels + 1 clock channel ([[P6451]] probe), impedance | 1 MΩ // 5 pF, max. ±40 V nondestructive, logic threshold fixed 1.4 V (TTL) or variable from -12 V to +12 V }} | ||
{{Spec | Word recognizer inputs | Sixteen TTL inputs (+40/-400 μA max.), max. +15/-1 V }} | |||
{{Spec | Serial / signature input | [[BNC connector]], 1 MΩ // 40 pF, max. ±250 V on BNC; used with [[P6107]] probe, 10 MΩ // 13 pF, max. ±500 V}} | {{Spec | Serial / signature input | [[BNC connector]], 1 MΩ // 40 pF, max. ±250 V on BNC; used with [[P6107]] probe, 10 MΩ // 13 pF, max. ±500 V}} | ||
{{Spec | Qualifier input | [[BNC connector]], 10 kΩ, max. +10/-5 V }} | {{Spec | Qualifier input | [[BNC connector]], 10 kΩ, max. +10/-5 V }} | ||
Line 16: | Line 17: | ||
{{Spec | Data timing | Setup time min. 25 ns, hold time min. 0 ns }} | {{Spec | Data timing | Setup time min. 25 ns, hold time min. 0 ns }} | ||
{{Spec | Memory | 2 × 252 eight-bit words (acquisition + reference) }} | {{Spec | Memory | 2 × 252 eight-bit words (acquisition + reference) }} | ||
{{Spec | Trigger mode | PRE (trigger at memory location 240) or POST (location 13) }] | |||
{{Spec | Trigger delay | 0-65535 clock periods }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
Revision as of 09:24, 27 May 2017
The Sony/Tektronix 308 is a portable 8-channel, 20 MHz "data analyzer" (logic analyzer) with parallel timing, parallel state, serial (up to 9600 bps) and signature analysis modes.
The 308 uses two probes, the standard P6451 8-channel + clock data acquisition probe, and the optional 16-channel P6406 word recognizer probe. Both use 012-0747-00 cable harnesses to attach to the data source.
Manuals
- Tektronix 308 Operator's Manual (PDF)
- Service manual / schematics needed
Key Specifications
{{Spec | Trigger mode | PRE (trigger at memory location 240) or POST (location 13) }]Parallel inputs | Eight data channels + 1 clock channel (P6451 probe), impedance |
---|---|
Word recognizer inputs | Sixteen TTL inputs (+40/-400 μA max.), max. +15/-1 V |
Serial / signature input | BNC connector, 1 MΩ // 40 pF, max. ±250 V on BNC; used with P6107 probe, 10 MΩ // 13 pF, max. ±500 V |
Qualifier input | BNC connector, 10 kΩ, max. +10/-5 V |
Sampling clock | 50 ns to 200 ms per sample (1-2-5 sequence) or external down to 50 ns |
Data timing | Setup time min. 25 ns, hold time min. 0 ns |
Memory | 2 × 252 eight-bit words (acquisition + reference) |
Trigger delay | 0-65535 clock periods |