[[File:P6056.jpg|thumb|350px|right|P6056 probe]] | |||
The '''Tektronix P6056''' is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972. | The '''Tektronix P6056''' is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972. | ||
Line 5: | Line 6: | ||
Its sister model [[P6057]] has ×100 attenuation. | Its sister model [[P6057]] has ×100 attenuation. | ||
< | <blockquote> | ||
<u>WARNING</u>: | |||
This high performance device has a fragile resistor assembly in the<br /> | |||
probe head, subject to failure in rough usage. Use with slip-on tip<br /> | |||
whenever possible. One replacement part is provided with the package.<br /> | |||
Contact nearest Field Office for additional parts (P/N 307-0330-00), if<br /> | |||
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4<br /> | |||
of manual. | |||
</ | </blockquote> | ||
==Manual== | ==Manual== |
Revision as of 11:44, 18 September 2017
The Tektronix P6056 is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the 7A19 amplifier in 1972.
It has an Identify switch and readout contact.
Its sister model P6057 has ×100 attenuation.
WARNING:
This high performance device has a fragile resistor assembly in the
probe head, subject to failure in rough usage. Use with slip-on tip
whenever possible. One replacement part is provided with the package.
Contact nearest Field Office for additional parts (P/N 307-0330-00), if
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4
of manual.
Manual
Key Specifications
Bandwidth | DC to 3.5 GHz |
---|---|
Rise time | 100 ps |
Attenuation | 10× |
Input impedance | 500 Ω // approx. 1 pF |
Scope Input | 50 Ω |
Features | Readout Pin, ID Button |