{{BeginSpecs}} | |||
{{Spec | Bandwidth | DC to 3.5 GHz }} | |||
{{Spec | Rise time | 100 ps }} | |||
{{Spec | Attenuation | 10× }} | |||
{{Spec | Input impedance | 500 Ω // approx. 1 pF }} | |||
{{Spec | Scope Input | 50 Ω }} | |||
{{Spec | Features | Readout Pin, ID Button }} | |||
{{EndSpecs}} | |||
==Manual== | |||
* [http://w140.com/tek_P6056_P6057.pdf Tektronix P6056 and P6057 Manual (PDF)] | |||
<blockquote> | <blockquote> | ||
Line 16: | Line 29: | ||
of manual. | of manual. | ||
</blockquote> | </blockquote> | ||
[[Category:50 Ohm Oscilloscope Probes]] | [[Category:50 Ohm Oscilloscope Probes]] | ||
[[Category:Introduced in 1972]] | [[Category:Introduced in 1972]] |
Revision as of 11:46, 18 September 2017
The Tektronix P6056 is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the 7A19 amplifier in 1972.
It has an Identify switch and readout contact.
Its sister model P6057 has ×100 attenuation.
Key Specifications
Bandwidth | DC to 3.5 GHz |
---|---|
Rise time | 100 ps |
Attenuation | 10× |
Input impedance | 500 Ω // approx. 1 pF |
Scope Input | 50 Ω |
Features | Readout Pin, ID Button |
Manual
WARNING:
This high performance device has a fragile resistor assembly in the
probe head, subject to failure in rough usage. Use with slip-on tip
whenever possible. One replacement part is provided with the package.
Contact nearest Field Office for additional parts (P/N 307-0330-00), if
required. For replacement and Calibration Procedure, refer to Pg. 3 & 4
of manual.