536: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 7: Line 7:
discontinued=1973 |
discontinued=1973 |
manuals=
manuals=
* [http://bama.edebris.com/manuals/tek/536 Tektronix 536 Manual (1961 edition, PDF)]
* [[Media:070-270.pdf | Tektronix 536 Manual (1961 edition, PDF, OCR)]]
* [http://w140.com/Tektronix_536_Oscilloscope_Manual_Dec1970_070-0270-01.pdf Tektronix 536 Manual (1970 edition, PDF)]
* [[Media:070-0270-01.pdf | Tektronix 536 Manual (1970 edition, PDF, OCR)]]
* [http://w140.com/tek_fcp/tek_type_536_early_factory_cal_proc.pdf Tektronix 536 Factory Calibration Procedure low-sn (PDF)]
* [[Media:Tek_536_fcp.pdf | Tektronix 536 Factory Calibration Procedure low-sn (PDF, OCR)]]
* [http://w140.com/tek_fcp/tek_type_536_late_factory_cal_proc.pdf Tektronix 536 Factory Calibration Procedure high-sn (PDF)]
* [[Media:Tek_536_fcp_high-sn.pdf | Tektronix 536 Factory Calibration Procedure high-sn (PDF, OCR)]]
 
* [[Media:070-0270-01.pdf|Tektronix 536 Manual (1970 edition, PDF, OCR)]]
* [[Media:tek_536_fcp.pdf|Tektronix 536 Factory Calibration Procedure low-sn (PDF, OCR)]]
* [[Media:tek_536_fcp_high-sn.pdf|Tektronix 536 Factory Calibration Procedure high-sn (PDF, OCR)]]
}}
}}


Line 22: Line 18:


The Type 536 does not contain trigger and sweep circuitry.   
The Type 536 does not contain trigger and sweep circuitry.   
To use a 536 as a conventional oscilloscope,
To use a 536 as a conventional oscilloscope, a [[T|Type T timebase plug-in]] can be installed in the Horizontal bay.
install a [[T|Type T]] timebase plug-in in the Horizontal bay.


The 536 contains identical vertical and horizontal amplifiers, with a front panel control to set the two in phase.
The 536 contains identical vertical and horizontal amplifiers, with a front panel control to set the two in phase.

Revision as of 04:14, 8 October 2018

{{{manufacturer}}} 
11 MHz X-Y scope
Tektronix 536 front

Produced from 1957 to 1973

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix Type 536 is an X-Y scope introduced in 1957 that takes two letter-series and 1-series plug-ins, one for the horizontal axis and one for the vertical axis.

The Type 536 does not contain trigger and sweep circuitry. To use a 536 as a conventional oscilloscope, a Type T timebase plug-in can be installed in the Horizontal bay.

The 536 contains identical vertical and horizontal amplifiers, with a front panel control to set the two in phase. This allows an equal bandwidth of 11 MHz in both directions. It also has a special CRT (T5360) with equal bandwidths in both directions. Aside from the amplifiers, the only other circuitry in the entire scope are the power supplies and calibrator.

Specifications

please add