1A4: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (Internals - identify switch, power supply)
(Specificaions)
Line 32: Line 32:
for scopes having this feature ([[544]], [[546]], [[547]], [[549]], [[556]], late [[555]]).
for scopes having this feature ([[544]], [[546]], [[547]], [[549]], [[556]], late [[555]]).


==Specifications==
{{BeginSpecs}}
[[Category:Specifications needed]] ''please add''
{{Spec | Plug-in Bandwidth | DC to 50 MHz }}
 
{{Spec | Maximum Input Sensitivity  | 10 mV/div }}
Maximum channel sensitivity is 10 mV/div,
{{Spec | Rise time | 7 ns }}
but a Signal Out jack makes it possible to cascade two channels
{{Spec | Input Impedance | 1 MΩ  // 20 pF }}
for approximately 200 μV/div AC with about 20 Hz - 1 MHz bandwidth. 
{{Spec | Maximum Input Voltage | 600 V combined DC and peak AC }}
{{Spec | Signal Output Impedence | 50 Ω}}
{{EndSpecs}}


Cascaded operation using the Signal Out jack can achieve a sensitivity of approximately 200 μV/div AC with about 20 Hz - 1 MHz bandwidth.
==Internals==
==Internals==
The signal path of each channel of the 1A4 is as follows.   
The signal path of each channel of the 1A4 is as follows.   

Revision as of 10:24, 24 December 2020

Template:Plugin Sidebar 2 The Tektronix Type 1A4 is a 1-series vertical plug-in for 500-series scopes. It has four input channels and 50 MHz bandwidth.

Type 1A4 was introduced in 1967 and lasted until the end of the 500-series scopes line.

The four channels are grouped into two groups of two channels. Type 1A4 has a special "trace slaving" mode which, when used in a 547 mainframe, allows channels 1 and 2 to be displayed using the A time base, and channels 3 and 4 to be displayed with the B time base. This allows high-speed and low-speed signals to be displayed together, similar to what a dual-beam scope can do, but without some of the cost and complexity.

Like the Type 1A2 and unlike the Type 1A1, the Type 1A4 has a Trigger Output selector that controls which channel provides triggering when the mainframe trigger is in Plug-In mode, for scopes having this feature (544, 546, 547, 549, 556, late 555).

Key Specifications

Plug-in Bandwidth DC to 50 MHz
Maximum Input Sensitivity 10 mV/div
Rise time 7 ns
Input Impedance 1 MΩ // 20 pF
Maximum Input Voltage 600 V combined DC and peak AC
Signal Output Impedence 50 Ω

Cascaded operation using the Signal Out jack can achieve a sensitivity of approximately 200 μV/div AC with about 20 Hz - 1 MHz bandwidth.

Internals

The signal path of each channel of the 1A4 is as follows. First the signal passes through the attenuators. Then it is clamped by two diodes and applied to the gate of a JFET source follower. The source of the source follower is the trigger pickoff point. From there the vertical signal path goes through an NPN emitter follower followed by an NPN differential amplifier, at which point the signal becomes differential. Next, the signal passes through an analog multiplexer made with 1N4152 silicon switching diodes. After the multiplexer network, the signal passes through a common base amplifier followed by 6DJ8 tube operating in common grid configuration.

There is an "identify" switch for each channel, which when pressed shifts the trace up by ~3mm, to aid identification of the corresponding signal/channel. This is achieved by offsetting position control circuitry with a small resistance to shift position.

The 12.1V and -15V power for the plug-in is generated onboard using a step-up transformer, whose primary is connected to the 6.3V heater supply from the mainframe and the two secondaries drive the onboard series regulators.


Pictures