5A26N: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(add manual from BAMA, selected specs from 1979 Tek catalog)
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=5000-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=5000-series scopes → designers=)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar|
title=Tektronix 5A26/5A26N |
manufacturer=Tektronix |series=5000-series scopes |type= 5A26/5A26N |
summary=Dual 1MHz differential amplifier |
summary=Dual 1MHz differential amplifier |
image=Tek 5a26 front close.jpg |  
image=Tek 5a26 front close.jpg |  
Line 6: Line 6:
introduced=1976 |
introduced=1976 |
discontinued=1991 |
discontinued=1991 |
series=[[5000-series scopes]]|
designers= |
manuals=
manuals=
* [[media:070-1947-00.pdf|Tektronix 5A26 Dual Differential Amplifier Instruction Manual (PDF)]]
* [[media:070-1947-00.pdf|Tektronix 5A26 Dual Differential Amplifier Instruction Manual (PDF)]]

Revision as of 00:04, 14 August 2021

Tektronix 5A26/5A26N
Dual 1MHz differential amplifier
Tektronix 5A26

Compatible with 5000-series scopes

Produced from 1976 to 1991

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 5A26/5A26N is a dual differential amplifier plug-in for 5000-series scopes.

Specifications

  • Sensitivity: 50 μV/div at 1 MHz
  • Bandwidth: DC to ≥1 MHz may be limited to 10 kHz
  • Deflection factor: 50 μV/div to 5 V/div cal.
  • CMRR (50 μV/div to 50 mV/div, DC to 30 kHz, ≤20 Vp-p sine wave): ≥100,000:1
  • CMRR (100 mV/div to 5 V/div, DC to 30 kHz, ≤100 Vp-p sine wave): ≥300:1
  • CMRR (AC coupled 50 μV/div to 50 mV/div, 5 kHz to 30 kHz): ≥20,000:1

Pictures