035-5031-00: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (part ref)
Line 3: Line 3:
* [[Media:061-1427-00.pdf|Tektronix 035-5031-00 Manual (PDF, OCR)]]
* [[Media:061-1427-00.pdf|Tektronix 035-5031-00 Manual (PDF, OCR)]]
}}
}}
It is a passive unit similar to one half of a [[7M11]] but in a TM500 plugin form factor so it be inserted into a TM500, TM5000 or [[5000-series scopes|5000-series oscilloscope]] mainframe, or operated standalone outside an enclosure.
It is a passive unit similar to one half of a [[7M11]] (and shares the same trigger pick-off/attenuator/compensator PCB, part [[670-1147-00]]), but in a TM500 plugin form factor so it be inserted into a TM500, TM5000 or [[5000-series scopes|5000-series oscilloscope]] mainframe, or operated standalone outside an enclosure.


Delay line connections are 50 Ω [[GR-874 connector]]s, the trigger output is through a [[BNC connector]].
Delay line connections are 50 Ω [[GR-874 connector]]s, the trigger output is through a [[BNC connector]].

Revision as of 08:38, 15 April 2023

Tektronix 035-5031-00
delay line
Tektronix 035-5031-00

Produced from 1977 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 035-5031-00 is a delay line plug-in for the TM500 system.

It is a passive unit similar to one half of a 7M11 (and shares the same trigger pick-off/attenuator/compensator PCB, part 670-1147-00), but in a TM500 plugin form factor so it be inserted into a TM500, TM5000 or 5000-series oscilloscope mainframe, or operated standalone outside an enclosure.

Delay line connections are 50 Ω GR-874 connectors, the trigger output is through a BNC connector.

Key Specifications

Impedance 50 Ω
Delay 75±1 ns
Rise time 175 ps
Attenuation ×2 (delayed output)
Trigger output attenuated ×5, 600 ps rise time

Photos