TM5006: Difference between revisions
No edit summary |
Jaredcabot (talk | contribs) (Added TM5006A manual with schematics.) |
||
Line 11: | Line 11: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-2950-00.pdf|Tektronix TM5006 Manual]] (82MB, OCR) | * [[Media:070-2950-00.pdf|Tektronix TM5006 Manual 070-2950-00]] (82MB, OCR) | ||
** [[Media:070-2950-00_2.pdf|Alternate copy]] (lower res, 13MB) | ** [[Media:070-2950-00_2.pdf|Alternate copy 070-2950-00]] (lower res, 13MB) | ||
* [[Media:070-7614-03.pdf|Tektronix TM5006A Manual (schematics missing)]] | * [[Media:Tek_TM5006A_Service_Manual_070-7614-03.pdf|Tektronix TM5006A Service Manual 070-7614-03]] | ||
** [[Media:070-7614-03.pdf|Tektronix TM5006A Manual (schematics missing) 070-7614-03]] | |||
}} | }} | ||
[[File:TM5006 rear.jpg | right | thumb | 250px ]] | [[File:TM5006 rear.jpg | right | thumb | 250px ]] |
Revision as of 07:16, 1 October 2023
The Tektronix TM5006 is a six-bay mainframe with a GPIB interface for the TM5000 system.
The rightmost compartment (slot 6) can supply high-powered plugins.
The DC rails to the plugins are provided by a switch-mode PSU. The supply is not universal input voltage, the input voltage must be set with two internal jumpers. DC rails are 8 V, +26 V, and −26 V. The case has a cooling fan which is connected to the primary of the transformer.
Available options include Opt.02, Rear Inputs, and Opt.10, a set of 19-inch rackmount slides.
For option 02, six BNC connectors and a 50-pin female DD-50 D-sub connector are installed on the rear panel and pin headers soldered internally, but no internal wiring is pre-installed.
The rack-mount kit has different sides compared to the standard model. It is not possible to remove the standard carry handle to install a rack-mount kit. The entire side panel must be swapped.
Specifications
please add
Input Voltage 115 V or 230 V nominal (selected with an internal jumper) with options for high, medium or low (100 V 110 V 120 V) or (200 V 220 V 240 V) using a second internal jumper.
Fan Flow Rate is higher in units with the 02 (rack-mount) option
Links
- TM5006 / TM5006A @ barrytech.com
- Zenwizard Studios Rebuild and Repair @ Zenwizard Studios You Tube
- Zenwizard Studios Rebuild and Repair II @ Zenwizard Studios You Tube
- TM5006 Mainframe load tester @ You Tube