CT-5: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(slightly condensed specs) |
||
Line 14: | Line 14: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | {{Spec | Bandwidth | 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil}} | ||
{{Spec | Risetime | 17.5 ns }} | |||
{{Spec | | {{Spec | Maximum pulsed current | 50 kA peak (with dearating)}} | ||
{{Spec | | |||
{{Spec | Accuracy | 4 % }} | {{Spec | Accuracy | 4 % }} | ||
{{Spec | Attenuation | 20:1 or 1000:1 }} | {{Spec | Attenuation | 20:1 or 1000:1 }} | ||
{{Spec | Input impedance | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz }} | {{Spec | Input impedance | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz }} | ||
{{Spec | Max. input voltage | 3000 V (bare conductor)}} | {{Spec | Max. input voltage | 3000 V (bare conductor) }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Revision as of 05:30, 22 November 2023
The Tektronix CT-5 High Current Transformer is designed to extend the range of an A6302 probe (with AM503 amplifier) or P6021 probe by a factor of 1000 (up to 5000 A/Div).
Key Specifications
Bandwidth | 0.5 Hz to 20 MHz with A6302; 12 Hz to 20 MHz with P6021; 1 Hz to 1 MHz with A6302/DC Bucking Coil |
---|---|
Risetime | 17.5 ns |
Maximum pulsed current | 50 kA peak (with dearating) |
Accuracy | 4 % |
Attenuation | 20:1 or 1000:1 |
Input impedance | 20 µΩ at 60 Hz to 30 mΩ at 1 MHz |
Max. input voltage | 3000 V (bare conductor) |