The 568 is a [[sampling oscilloscope]] that was [[introduced in 1967]] that takes 3S- and 3T-series plug-ins. | The 568 is a [[sampling oscilloscope]] that was [[introduced in 1967]] that takes 3S- and 3T-series plug-ins. | ||
Although it was intended to be used for sampling, it can also be used with non-sampling plug-ins | Although it was intended to be used for sampling, it can also be used with non-sampling plug-ins of the 3A and 3B series. | ||
of the 3A and 3B series. | |||
Like the [[561]] and [[564]], the 568 does not contain vertical or horizontal amplifiers. | Like the [[561]] and [[564]], the 568 does not contain vertical or horizontal amplifiers. The plug-ins directly drive the deflection plates. The 568 has multipin connectors on its rear panel that are routed to multipin connectors on the plug-ins. This is to support external control and measurement using, for example, a [[230]] and [[241]]. | ||
The plug-ins directly drive the deflection plates. | |||
The 568 has multipin connectors on its rear panel | |||
that are routed to multipin connectors on the plug-ins. | |||
This is to support external control and measurement using, for example, a [[230]] and [[241]]. | |||
Two sampling heads can be interfaced directly to the 568 using the [[012-0130-00]] cable, or | Two sampling heads can be interfaced directly to the 568 using the [[012-0130-00]] cable, or | ||
multiple sampling heads can be interfaced using an multiplexer such as the [[286]], [[287]], | multiple sampling heads can be interfaced using an multiplexer such as the [[286]], [[287]], | ||
Line 15: | Line 23: | ||
such as the [[S-3100]]. | such as the [[S-3100]]. | ||
A modification, 708P, was available for the 568 to give it a head multiplexer instead of a CRT. | |||
A modification, 708P, was available for the 568 to give it a head multiplexer instead of a | |||
CRT. | |||
==Specifications== | |||
[[Category:Specifications needed]] | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Line 31: | Line 38: | ||
[[Category:560 series scopes]] | [[Category:560 series scopes]] | ||
[[Category: | [[Category:Sampling scopes]] | ||
[[Category:Image needed]] |
Revision as of 05:39, 19 May 2014
The 568 is a sampling oscilloscope that was introduced in 1967 that takes 3S- and 3T-series plug-ins. Although it was intended to be used for sampling, it can also be used with non-sampling plug-ins of the 3A and 3B series.
Like the 561 and 564, the 568 does not contain vertical or horizontal amplifiers. The plug-ins directly drive the deflection plates. The 568 has multipin connectors on its rear panel that are routed to multipin connectors on the plug-ins. This is to support external control and measurement using, for example, a 230 and 241.
Two sampling heads can be interfaced directly to the 568 using the 012-0130-00 cable, or multiple sampling heads can be interfaced using an multiplexer such as the 286, 287, or R288.
The 568 was distributed as a self-contained instrument and also as a component of integrated test and measurement systems such as the S-3100.
A modification, 708P, was available for the 568 to give it a head multiplexer instead of a CRT.
Specifications
Pictures
-
568 Mod 708P front
-
568 Mod 708P head multiplexer circuitry
-