Active Probes

Revision as of 12:56, 9 April 2020 by Gregor (talk | contribs)

Active Probes contain an active element like a FET or a tube right at the tip of the probe. This allows to eliminate cable loading and create higher input impedances, most useful for high frequency probing.

Specification Summary (Please Expand)
Model Attenuation Length Input Loading Bandwidth
GHz
Dynamic Range Offset Range Max. Voltage Target
Impedance
Power Source Readout
pin
R / MΩ C / pF
P6032 10x 6ft. 10 3.6 0.85 ±1.5 V N/A 1.5× Dyn. Range 50 Ω 4-pin 1S1 type N
20x 2.6 ±3 V
50x 3 ±7.5 V
100x 1.5 ±15 V
200x 1.4 ±30 V
500x 1.3 ±75 V
1000x 1.3 ±150 V
P6201 100x 6ft. 1 1.5 1.1 ±60 V ±200 V 200 V 50 Ω 7000 Series Lemo Y
10x 1 1.5 1.1 ±6 V ±56 V 200 V
1x 0.1 3 1.1 ±06 V ±5.6 V 50 V
P6202A 100x 2m 10 2 0.5 ±60 V ±200 V 200 V 50 Ω 7000 Series Lemo Y
10x 10 2 0.5 ±6 V ±55 V 200 V
P6204 10x 1.5m 10 1.9 1 ±10 V ±15 V 40 V 50 Ω Tekprobe BNC connector N/A
P6207 10x 1m 0.1 0.4 4 ±4 V ±5 V 40 V 50 Ω Tekprobe SMA connector N/A
P6249 5x 1.3m 20 kΩ 1.0 4 ±2 V ±5 V 30 V 50 Ω Tekprobe BNC connector N/A
P7260 5x 1.3m 20 kΩ 0.5 6 ±0.75 V ±5 V 30 V 50 Ω TekConnect connector N/A
25x ±3 V