39,764
edits
(Redirected page to 2465A) |
(Removed redirect to 2465A) Tag: Removed redirect |
||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | |||
|manufacturer=Tektronix | |||
|series=2400-series scopes | |||
|model=2467 | |||
|summary=Portable 350/400 MHz 4-ch micro-channel scope | |||
|image=Tek 2467 bright.jpg | |||
|caption=Tektronix 2467 | |||
|introduced=1986 | |||
|discontinued=(?) | |||
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth | |||
|manuals= | |||
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes]] | |||
* [[Media:070-5857-00.pdf|24x5A Options Service]] (OCR PDF, 26M) | |||
* [[Media:070-6014-00.pdf|24x5A Operator]] | |||
* [[Media:070-6017-00.pdf|2455A/2445A Service]] (OCR PDF, 20M) | |||
* [[Media:070-6019-01.pdf|2465A/2467 Service]] (OCR PDF, 29M) | |||
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit (PDF, needs OCR)]] | |||
}} | |||
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals. | |||
The 2467 is from the penultimate generation of analog Tektronix scopes. | |||
The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps. | |||
'''Options''' | |||
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature. | |||
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering. | |||
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering. | |||
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]]. | |||
* Option 10 added a [[GPIB interface]] for remote control. | |||
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument. Only shown in the 1987 catalogue. | |||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 350 MHz (2467B: 400 MHz) }} | |||
{{Spec | Sweep Rate | 500 ps/div }} | |||
{{Spec | Channels | Four independent channels }} | |||
{{Spec | Vertical | 2 mV/div vertical sensitivity }} | |||
{{Spec | Cursors | Delta Volts and Delta Time Cursors }} | |||
{{Spec | CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators }} | |||
{{Spec | Trigger | 500 MHz min.; Advanced Triggering with "Hands Off" Auto Level Triggering }} | |||
{{Spec | Input Impedance | 50 Ω/1 MΩ inputs with 50 Ω protection }} | |||
{{Spec | Probes | Two or four [[P6136]] ×10 probes, 1.3 m }} | |||
{{EndSpecs}} | |||
==See also== | |||
* [[2465]] | |||
* [[2465B]] | |||
* [[2445 PSU Repairs|PSU Repairs]] | |||
==Pictures== | |||
<gallery> | |||
Tek 2467 bright.jpg | |||
Tek 2467 rear.jpg | |||
</gallery> | |||
[[Category:246x series scopes]] | [[Category:246x series scopes]] | ||
[[Category:Introduced in 1986]] | |||
[[Category:Micro-channel plate CRTs]] | [[Category:Micro-channel plate CRTs]] |