{{Oscilloscope Sidebar
|manufacturer=Tektronix
|series=2400-series scopes
|model=2467
|summary=Portable 350/400 MHz 4-ch micro-channel scope
|image=Tek 2467 bright.jpg
|caption=Tektronix 2467
|introduced=1986
|discontinued=(?)
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|manuals=
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes]]
* [[Media:070-5857-00.pdf|24x5A Options Service]] (OCR PDF, 26M)
* [[Media:070-6014-00.pdf|24x5A Operator]]
* [[Media:070-6017-00.pdf|2455A/2445A Service]] (OCR PDF, 20M)
* [[Media:070-6019-01.pdf|2465A/2467 Service]] (OCR PDF, 29M)
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit (PDF, needs OCR)]]
}}
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
 
The 2467 is from the penultimate generation of analog Tektronix scopes.
 
The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
 
'''Options'''
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 added a [[GPIB interface]] for remote control.
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.
 
{{BeginSpecs}}
{{Spec | Bandwidth      | 350 MHz (2467B: 400 MHz) }}
{{Spec | Sweep Rate      | 500 ps/div }}
{{Spec | Channels        | Four independent channels }}
{{Spec | Vertical        | 2 mV/div vertical sensitivity }}
{{Spec | Cursors        | Delta Volts and Delta Time Cursors }}
{{Spec | CRT Readout    | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators }}
{{Spec | Trigger        | 500 MHz min.; Advanced Triggering with "Hands Off" Auto Level Triggering }}
{{Spec | Input Impedance | 50 Ω/1 MΩ inputs with 50 Ω protection }}
{{Spec | Probes          | Two or four [[P6136]] ×10 probes, 1.3 m  }}
{{EndSpecs}}
 
==See also==
* [[2465]]
* [[2465B]]
* [[2445 PSU Repairs|PSU Repairs]]
 
==Pictures==
<gallery>
Tek 2467 bright.jpg
Tek 2467 rear.jpg
</gallery>




[[Category:246x series scopes]]
[[Category:246x series scopes]]
[[Category:Introduced in 1986]]
[[Category:Micro-channel plate CRTs]]
[[Category:Micro-channel plate CRTs]]

Navigation menu