{{{manufacturer}}} 
50 MHz scope
Tektronix 547 with 1A2 plugin

Produced from 1964 to 1975

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 547 is a 50 MHz scope that takes letter-series and 1-series plug-ins. It has two identical timebases and, when used with the 1A1, 1A2, or 1A4, has the ability to display one input with one time scale and another input with a different time scale. The effect is similar to a dual-beam scope assuming that the input signals are repetitive. This "Sweep Switching" feature differentiates the 547 from the 546.

There is also a rackmount version, the RM547 or R547.

The project lead for the development of the Tektronix 544, 546, and 547 was Bob Rullman.

Internals

Triggering

Triggering is done with tunnel diodes. The 'A' trigger is based on a 10 mA tunnel diode. Up to serial number 11889, it uses a TD253. From 11890 onward, it uses a 152-0140-01.

CRT

The 547 uses the Tektronix 154-0478-00 CRT.

HV Transformer

A common problem with 547s is the HV transformer. Rather than potting the HV transformer in wax, as was done up to that point, the 547's HV transformer was potted in epoxy. Unfortunately, this epoxy turned out to absorb moisture over time, particularly when used in humid climates. The moisture causes increased losses in the transformer. Excessive losses require the regulator to drive the 6AU5 input oscillator tube (V800) harder. Eventually, the drive circuit cannot supply enough power to keep the supply in regulation. The usual solution is to scavenge a replacement transformer from another scope. As a labor of love, hobbyists have been known to rebuild the HV transformers. This is discussed from time to time on the Yahoo TekScopes forum.

Vertical Amplifier

The 547 has a five-stage BJT vertical amplifier that is fully differential from the plug-in connector to the CRT vertical deflection plates. There is one tube in the vertical signal path, a 12AT7 acting as a unity-gain buffer between the plug-in connector and the vertical amplifier.

There is a 170 nanosecond delay line between the first and second gain stages.

Power Supply

The 547's power supply provides regulated outputs of −150 V, +100 V, +225 V, +350 V, as well as a +325 V unregulated output for CRT HV section.


Multiple secondary windings feeds diodes for rectification for different voltages. Both center-tap and bridge configuration is used. Its a all Tube design for the regulation. There are multiple 6.3V secondary outputs for heaters, many elevated to different voltage levels based on the section/tube its used for to keep the Heater-Cathode voltage level within limits.

As is common in many Tektronix scopes, all regulated voltages are referred to the negative regulated rail (−150 V in this case) by fixed low-tolerance dividers. Only the −150 V voltage is trimmed, its reference is a OG3 VR tube. A 12AX7 is used as the comparator, two 6CW5 in parallel are used as series pass tubes. A 6AU6 is used as an error amplifier.

Most other stages replicate the same design, except slight changes in tubes used − the , +225 V and +100 V regulators employ a 6080 as the pass element, +350 uses a 6CW5 - and reference for them is the -150V


The plate voltage delay circuit is as like in may other Teks, uses a 6N030 delay tube (P/N 148-0021-00) to control a relay that switches plate supply voltages on only after the tubes are warmed up. Heater voltage is directly applied to tubes on Power on.


Links