3T6: Difference between revisions
No edit summary |
No edit summary |
||
(9 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | ||
|manufacturer=Tektronix | |||
summary=Programmable Sampling Sweep | | |series=560-series scopes | ||
image= | |type=3T6 | ||
caption=3T6 sweep unit | | |summary=Programmable Sampling Sweep | ||
|image=3T6_front.JPG | |||
introduced=1969 | | |caption=3T6 sweep unit | ||
discontinued=(?) | | |designers= | ||
manuals= | |introduced=1969 | ||
* http://bama.edebris.com/manuals/tek/3t6/ | |discontinued=(?) | ||
|manuals= | |||
* [[Media:070-0761-00.pdf|Tektronix 3T6 manual]] (PDF) | |||
* [http://bama.edebris.com/manuals/tek/3t6/ 3T6 manual @ BAMA] (DJvu) | |||
}} | }} | ||
The '''Tektronix Type 3T6''' is a [[sampling_oscilloscope|sampling]] | The '''Tektronix Type 3T6''' is a [[sampling_oscilloscope|sampling]] plug-in for [[560-series scopes]]. | ||
plug-in for [[560-series scopes]]. It is particularly suited, | It is particularly suited, and programmable, when used in a [[568]]. | ||
and programmable, when used in a [[568]]. | |||
In addition to the usual two 560-series connectors on the rear of the plug-in, | In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23. | ||
the 3T6 has two extra connectors, J24 and P23. | J24 is used for programming the 3T6. P23 is a coaxial feed (via a [[Gremar connector]]) of the trigger input signal. | ||
P23 is a coaxial feed (via a [[ | |||
Both of these connectors mate with corresponding connectors in the 568. | Both of these connectors mate with corresponding connectors in the 568. | ||
The 3T6 contains a digital delay that controls the time between | The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started. | ||
when the trigger event is recognized and when the sweep ramp is started. | The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event. | ||
The purpose of this delay is the same as any delayed sweep: to zoom in | The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24. | ||
on a region of a waveform that is not immediately after the trigger event. | |||
The digital delay in the 3T6 can be controlled by digital rotary switches | |||
on the front panel of the 3T6 or remotely, through the 568, via connector J24. | |||
Mod 651C give 100 / 1000 samples/sweep switch. The original has 1 / 1000 samples/sweep switch. Later units appear to have the 100 / 1000 switch as standard. | |||
'' | The indicator lamps in the 'Time/Div' display can occasionally burn out. They can be replaced with 5V, 80mA, 2.5mm x 4.5mm, 'grain of wheat' style lamps. | ||
{{MissingSpecs}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
3t6_front.JPG|3T6 Mod 651C front view | |||
3T6_front.JPG|3T6 front view | |||
3t6_right.JPG|right view | |||
3t6_top.JPG|top view | |||
3t6_bottom.JPG|bottom view | |||
3t6_rear.JPG|rear view | |||
</gallery> | </gallery> | ||
{{Parts|3T6}} | |||
[[Category:560 series plugins]] | [[Category:560 series plugins]] | ||
[[Category:Sampling plugins]] | [[Category:Sampling plugins]] |
Revision as of 16:44, 24 June 2022
The Tektronix Type 3T6 is a sampling plug-in for 560-series scopes. It is particularly suited, and programmable, when used in a 568.
In addition to the usual two 560-series connectors on the rear of the plug-in, the 3T6 has two extra connectors, J24 and P23. J24 is used for programming the 3T6. P23 is a coaxial feed (via a Gremar connector) of the trigger input signal. Both of these connectors mate with corresponding connectors in the 568.
The 3T6 contains a digital delay that controls the time between when the trigger event is recognized and when the sweep ramp is started. The purpose of this delay is the same as any delayed sweep: to zoom in on a region of a waveform that is not immediately after the trigger event. The digital delay in the 3T6 can be controlled by digital rotary switches on the front panel of the 3T6 or remotely, through the 568, via connector J24.
Mod 651C give 100 / 1000 samples/sweep switch. The original has 1 / 1000 samples/sweep switch. Later units appear to have the 100 / 1000 switch as standard.
The indicator lamps in the 'Time/Div' display can occasionally burn out. They can be replaced with 5V, 80mA, 2.5mm x 4.5mm, 'grain of wheat' style lamps.
Key Specifications
- please add
Pictures
-
3T6 Mod 651C front view
-
3T6 front view
-
right view
-
top view
-
bottom view
-
rear view
Some Parts Used in the 3T6
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
SMTD994 | 152-0177-01 | Discrete component | 10 mA, 2 pF tunnel diode | 067-0587-01 • 067-0580-00 • 3T5 • 3T6 • 485 • 5S14N • 7D14 • 7T11 • 7T11A • S-53 |
SMTD995 | 152-0140-01 | Discrete component | 10 mA, 8 pF tunnel diode | 1S1 • 1S2 • 1502 • 21A • 22A • 3T5 • 3T6 • 475 • 475A • 475M • 544 • R544 • 546 • RM546 • 547 • RM547 • 556 • R556 • 581A • 585A • RM585 • 7B52 • 7B53N • 7B70 • 7B71 • 7D10 • 7D11 • 7T11 • 7T11A • R7912 • S-51 • S-52 • TU-5 • 067-0572-00 • 067-0572-01 • 067-0681-00 |