543: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 17: Line 17:


While the 545 has two non-calibrated X-input sensitivities, the 543 has
While the 545 has two non-calibrated X-input sensitivities, the 543 has
an X-input with three calibrated selectable deflection sensitivities: 0.1 V/cm, 1 V/cm, and
an X-input with three calibrated selectable deflection sensitivities: 0.1 V/cm, 1 V/cm, and 10 V/cm.
10 V/cm.


The standard CRT for the 543 is the [[T65]] with P2 [[phosphor]], part number 154-175.
The standard CRT for the 543 is the [[T65]] with P2 [[phosphor]], part number 154-175.
The standard CRT for the 543B is part number [[154-0478-00]], also known as the T5470-31-2.
The standard CRT for the 543B is part number [[154-0478-00]], also known as the T5470-31-2.


The total acceleration voltage on the CRT is 10 kV.
The total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five [[5642]] HV tube diodes.
The CRT power supply uses five [[5642]] HV tube diodes.


543B is a hybrid and vertical delay line have no 6DK6 and LC but 186 ohms [[delay line]].
The '''543B''' is a tube/transistor hybrid scope. The vertical amplifier has a [[6DJ8]] cathode follower stage followed by two transistor/tube cascode stages with a 186 Ω [[delay line]] inbetween.


==Specifications==
==Specifications==

Revision as of 23:15, 17 May 2017

Manuals – Specifications – Links – Pictures

The Tektronix Type 543 (rack mount RM43) is an all-tube 30 MHz scope introduced in 1958. It takes letter-series and 1-series plug-ins. It is similar to a 545, but without the second, delayed timebase. Instead, it has a range of horizontal magnifiers from ×2 to ×100. It has the same six-stage balanced distributed amplifier (twelve 6DK6 tubes) as the 545.

While the 545 has two non-calibrated X-input sensitivities, the 543 has an X-input with three calibrated selectable deflection sensitivities: 0.1 V/cm, 1 V/cm, and 10 V/cm.

The standard CRT for the 543 is the T65 with P2 phosphor, part number 154-175. The standard CRT for the 543B is part number 154-0478-00, also known as the T5470-31-2.

The total acceleration voltage on the CRT is 10 kV. The CRT power supply uses five 5642 HV tube diodes.

The 543B is a tube/transistor hybrid scope. The vertical amplifier has a 6DJ8 cathode follower stage followed by two transistor/tube cascode stages with a 186 Ω delay line inbetween.

Specifications

please add

Pictures