602: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 10: | Line 10: | ||
|designers=Bob Shand; | |designers=Bob Shand; | ||
|manuals= | |manuals= | ||
* [[Media:070-0799-00.pdf|Tektronix 602 Manual]] | * [[Media:070-0799-00.pdf|Tektronix 602 Manual]] | ||
* [http://www.bitsavers.org/pdf/dec/unibus/EK-AA11K-TM-001_Jul76.pdf DEC Manual Discussing the Tek 602] | * [http://www.bitsavers.org/pdf/dec/unibus/EK-AA11K-TM-001_Jul76.pdf DEC Manual Discussing the Tek 602] | ||
* [[Media:Tek 602 fcp august 1968.pdf|Tektronix 602 Factory Calibration Procedure, August 1968 | * [[Media:Tek 602 fcp august 1968.pdf|Tektronix 602 Factory Calibration Procedure, August 1968]] | ||
}} | }} | ||
The '''Tektronix 602''' is an X-Y display. | The '''Tektronix 602''' is an X-Y display. | ||
Line 22: | Line 22: | ||
The trace width is 14 mils at 0.5 μA beam current. | The trace width is 14 mils at 0.5 μA beam current. | ||
The 602 has a linear power supply. The CRT does not use post-deflection acceleration, and has | The 602 has a linear power supply. The CRT does not use post-deflection acceleration, and has –3,830 volts on the cathode. | ||
== | {{MissingSpecs}} | ||
==Links== | |||
{{Documents|Link=602 }} | |||
{{PatentLinks|602}} | |||
==Pictures== | ==Pictures== | ||
Line 39: | Line 41: | ||
Tek602grat.jpg|602 showing illuminated 8x10 graticule | Tek602grat.jpg|602 showing illuminated 8x10 graticule | ||
</gallery> | </gallery> | ||
==Coomponents== | |||
{{Parts|602}} | |||
[[Category:600 series CRT monitors]] | [[Category:600 series CRT monitors]] |
Latest revision as of 09:14, 16 July 2024
The Tektronix 602 is an X-Y display.
It has differential X and Y inputs, each with 100 mV/div sensitivity.
The bandwidth of the X and Y amplifiers is 1 MHz, and their phase response is matched within 1 degree from DC to 1 MHz. The standard phosphor is P31 (yellowish green, medium-short persistence). P7 phosphor (blueish white, long persistence) was optional. The trace width is 14 mils at 0.5 μA beam current.
The 602 has a linear power supply. The CRT does not use post-deflection acceleration, and has –3,830 volts on the cathode.
Key Specifications
- please add
Links
Documents Referencing 602
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1969 V1 N3 Jun 1969.pdf | Article | A New Look in Information Display | 1969 | 601 • 602 • 611 • 4501 • T4002 | |
History of the Information Display Division - John Lamb, June 1974.pdf | Article | History of the Information Display Division | John Lamb | 1974 | Information Display Division • 601 • 611 • 602 • 4002 • 4501 • 4005 • 4601 • 4901 • 4951 • 4002A • 4551 • 4701 • Tekplot • 4602 • 4010 • 4610 • 4911 • 4912 • 613 • 4903 • 4012 • 4013 • 4014 • 4015 • 4023 • 4503 • 4921 • 4922 • 4953 • 4954 |
Pictures
-
Front
-
-
Top internal
-
Rear
-
-
Deflection Amplifiers
-
602 with vectorscope graticule
-
602 showing illuminated 8x10 graticule
Coomponents
Some Parts Used in the 602
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0562-00 | 154-0562-00 | CRT | direct-view storage CRT | 602 |
154-0753-00 | 154-0753-00 • 154-0753-04 • 154-0754-00 • 154-0754-04 • 154-0755-00 • 154-0755-04 | CRT | direct-view storage CRT | 602 |