* ''A/B Sweep'' − 500 mV<sub>p-p</sub>, negative-going copy of sweep signal from timebase, not affected by X position control or magnifier; Used for mainframe's Sawtooth Out, additionally fed to V plugins
* ''A/B Sweep'' − 500 mV<sub>p-p</sub>, negative-going copy of sweep signal from timebase, not affected by X position control or magnifier; Used for mainframe's Sawtooth Out, additionally fed to V plugins
* ''Line Trigger'' − Approx. 1 V<sub>RMS</sub> mains-frequency signal from power supply (through transformer)
* ''Line Trigger'' − Approx. 1 V<sub>RMS</sub> mains-frequency signal from power supply (through transformer)
* ''Trigger Holdoff'' −
* ''Trigger Holdoff'' − 0/+5 V, generated by time-base, high during holdoff time of time-base, used in mainframe for ALT sequencing.
* ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in.
* ''Chop Drive'' − 0/+5 V; switches at one-half the rate of the VERTICAL MODE CHOP signal; high level selects channel 2, low level selects channel 1 of a dual-trace plug-in.
* ''Chop Mode Sense'' −  
* ''Chop Mode Sense'' −  
Line 124: Line 124:
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]]
* ''Intensity Limit'' − Switched to ground by timebase in slow sweep speeds (≥100 ms/Div), limits beam intensity to protect the CRT [[phosphor]]
* ''Mainframe Channel Switch'', ''Mainframe Mode'' − 0/+5 V logic levels; plug-in output is displayed when MF Channel Switch ≠ MF Mode (XOR)
* ''Mainframe Channel Switch'', ''Mainframe Mode'' − 0/+5 V logic levels; plug-in output is displayed when MF Channel Switch ≠ MF Mode (XOR)
* ''Sweep Inhibit''
* ''Sweep Inhibit/Sweep Lockout'' - Mainframe injects current > 1mA to prevent time base from sweeping. Used for ALT sequencing.
* ''Delay Gate'' − negative-going pulse starting at the end of the delay period, and lasting until the end of the sweep from the delaying timebase. +Gate Output on mainframe uses Delay Gate from H slot B when Delay Gate is selected.  Grounded in amplifier plugins.
* ''Delay Gate'' − negative-going pulse starting at the end of the delay period, and lasting until the end of the sweep from the delaying timebase. +Gate Output on mainframe uses Delay Gate from H slot B when Delay Gate is selected.  Grounded in amplifier plugins.
* ''Single sweep ready'' − 0/+5 V, high when single sweep is ready  
* ''Single sweep ready'' − 0/+5 V, high when single sweep is ready  