Page values for "7B10"

Jump to navigation Jump to search

"Products" values

1 row is stored for this page
Manufacturer   Tektronix
Model   7B10
Class   Plug-in
Description   

1 GHz timebase

Series   7000-series scopes
Introduced   1978
Designers   Art Metz Bruce Hofer Val Garuts
Discontinued   1990

"Specifications" values

7 rows are stored for this page
Parameter   Sweep
Value   

200 ms/Div to 2 ns/Div in 1−2−5 sequence, ×10 magnifier down to 200 ps/Div, variable to ×2.5

Parameter   Excluded portions of sweep
Value   

None in 7104/R7103, first 5 ns in 78xx, 79xx mainframes

Parameter   Trigger sensitivity
Value   

0.5 Div (int) or 50 mV (ext) up to 250 MHz, 1.5 Div or 150 mV from 250 MHz to 1 GHz; HF SYNC mode: 0.3 Div or 75 mV, 250 MHz to 1 GHz

Parameter   Trigger coupling
Value   

DC, AC (>30 Hz), AC HF REJ (30 Hz to 30 kHz), AC LF REJ (>50 kHz)

Parameter   Trigger input
Value   

50 Ω, max. 1 W average or 1 MΩ // 20 pF, max. 250 V DC+peak AC

Parameter   Jitter
Value   

less than 30 ps at 1 GHz

Parameter   Features
Value   
  • Variable Trigger Holdoff
  • HF Sync mode