CSA803: Difference between revisions

199 bytes added ,  18 April 2018
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
[[File:csa803.jpg|400px|thumb|right|CSA803A]]
{{Oscilloscope Sidebar |
 
title=Tektronix CSA803 |
The '''Tektronix CSA803''' is a digital sampling oscilloscope that takes two [[:Category:11800 series sampling plugins|11800 series plug-in sampling modules]]. The two left plug-in slots are supplying DC only and are supposed to be used for optical to electrical converters like the [[SD-48]]. From the specifications of the CSA803C and the 11801C it seems that they are identical, except for omitting the two left plug-ins and the trigger x10 function in the CSA803.
summary=Digital Sampling Scope |
 
image=csa803.jpg|400px|thumb|right|CSA803A]] |
==Manuals==
caption=Tektronix CSA803A |
* [http://w140.com/tek_csa803a_service.pdf Tektronix CSA803A Service Manual (PDF)]
introduced=(?) |
* [[Media:070-9974-01.pdf|Tektronix CSA803C Service Manual (PDF)]]
discontinued=(?) |
 
manuals=
* [http://w140.com/tek_csa803a_service.pdf CSA803A Service Manual (PDF)]
* [[Media:070-9974-01.pdf| CSA803C Service Manual (PDF)]]
}}
The '''Tektronix CSA803''' is a digital sampling oscilloscope that takes two [[:Category:11800 series sampling plugins|11800 series plug-in sampling modules]]. The two left plug-in slots are supplying DC only and are supposed to be used for optical to electrical converters like the [[SD-48]]. From the specifications of the CSA803C and the [[11801C]] it seems that they are identical, except for omitting the two left plug-ins and the trigger ×10 function in the CSA803.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Vertical Resolution | 8 bits - 25points/div }}
{{Spec | Vertical Resolution | 8 bits - 25 points/div }}
{{Spec | Input Sensitivity | 2 to 255 mV/div in 1 mV/div steps}}
{{Spec | Input Sensitivity | 2 to 255 mV/div in 1 mV/div steps}}
{{Spec | Record Duration | 10 ps to 50 ms}}
{{Spec | Record Duration | 10 ps to 50 ms}}
{{Spec | Record Length | 512, 1024, 2048, 4096, 5120 samples}}
{{Spec | Record Length | 512, 1024, 2048, 4096, 5120 samples}}
{{Spec | Sample Rate | up to 200 kHz}}
{{Spec | Sample Rate | up to 200 kHz}}
{{Spec | Jitter | 1.1ps RMS + 4ppm of position (typical) }}
{{Spec | Jitter | 1.1 ps RMS + 4 ppm of position (typical) }}
{{Spec | Maximum Trigger Input | 1Vpp direct, 2.5Vpp Prescaler }}
{{Spec | Maximum Trigger Input | 1 V<sub>p-p</sub> direct, 2.5 V<sub>p-p</sub> prescaler }}
{{Spec | Trigger Sensitivity | 50mV, DC - 4GHz, AC coupled trigger prescaler to 10GHz}}
{{Spec | Trigger Sensitivity | 50 mV, DC - 4 GHz, AC coupled trigger prescaler to 10 GHz}}
{{EndSpecs}}
{{EndSpecs}}


==Prices==
==Prices==
1990: $23,950
1990: $23,950 (2018 value: $45,730)


==Links==
==Links==