P6156: Difference between revisions

1,107 bytes added ,  14 January 2023
no edit summary
mNo edit summary
No edit summary
 
(6 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{Probe Sidebar
|manufacturer=Tektronix
|model=P6156
|summary=3.5 GHz passive probe
|image=P6156.jpg
|caption=P6156 probe
|for=50 Ω scope inputs
|introduced=1989
|discontinued=(?)
|manuals=
* [[Media:070-6430-01.pdf|Tektronix P6156 Manual]]
}}
The '''Tektronix P6156''' is a DC to 3.5 GHz, compact size, fast-rise, low input capacitance, passive voltage probe with a constant input resistance over a wide range of frequencies. It is designed for use with wide band oscilloscope amplifiers with 50 Ω inputs, such as the Tektronix [[11000-series scopes]] with the [[11A71]] plug-in.  
The '''Tektronix P6156''' is a DC to 3.5 GHz, compact size, fast-rise, low input capacitance, passive voltage probe with a constant input resistance over a wide range of frequencies. It is designed for use with wide band oscilloscope amplifiers with 50 Ω inputs, such as the Tektronix [[11000-series scopes]] with the [[11A71]] plug-in.  


Options were available for  ×1,  ×10, ×20 or ×100 attenuation (×1 and ×100 versions with 1.5 GHz bandwidth), with attenuator tips color coded for identification.  
Options were available for ×1 (Opt. 27), ×10, ×20 (Opt.26) or ×100 (Opt.25) attenuation (×1 and ×100 versions with 1.5 GHz bandwidth), with attenuator tips color coded for identification.
The termination box has a switch that sets the readout resistor accordingly (×20 is recognized only on 11000 series, not on 7000).


An “identify” button on the probe head provides trace identity and allows control of one or more programmable functions in 11000 Series oscilloscopes.  
An “identify” button on the probe head provides trace identity and allows control of one or more programmable functions in 11000 Series oscilloscopes.  
Line 7: Line 20:
The P6156 is equipped with a [[BNC connector]] that provides trace identify and digital readout information.  
The P6156 is equipped with a [[BNC connector]] that provides trace identify and digital readout information.  


==Manual==
==Specifications==
* http://w140.com/tek_p6156.pdf
{| class="wikitable" |
! Model
!width="100px" | ×1
!width="100px" | ×10
!width="100px" | ×20
!width="100px" | ×100
|-
! align="right" style="padding-right: 0.8em;"| Input Impedance
| 50 Ω
| 500 Ω // ≤1 pF
| 1 kΩ // ≤1 pF
| 5 kΩ // ≤2.1 pF
|-
! align="right" style="padding-right: 0.8em;"| Max. Input
| 15 V<sub>RMS</sub>
| 15 V<sub>RMS</sub>
| 22 V<sub>RMS</sub>
| 50 V<sub>RMS</sub>
|-
! align="right" valign="top" style="padding-right: 0.8em;"| Bandwidth
| ≥1.5 GHz
| ≥3.5 GHz
| ≥3.5 GHz
| ≥1.5 GHz
|-
! align="right" valign="top" style="padding-right: 0.8em;"| Rise Time
| ≤300 ps
| ≤100 ps
| ≤100 ps
| ≤233 ps
|-
|}


{{MissingPics}}


[[Category:50 Ohm Oscilloscope Probes]]
[[Category:50 Ω Oscilloscope probes]]
[[Category:Introduced in 1989]]
[[Category:Compact modular probes]]
1,874

edits