* Markers: 5 s to 1 ns in a 1,2,5 sequence
* Markers: 5 s to 1 ns in a 1,2,5 sequence
* Marker Amplitude: ≥1V peak on 5s through 10 ns; ≥750 mV<sub>p-p</sub> on 5 ns and 2 ns; ≥ 200 mV<sub>p-p</sub>V on 1 ns - All values into 50 Ohm
* Marker Amplitude (into 50 Ω): ≥1 V peak on 5 s through 10 ns; ≥750 mV<sub>p-p</sub> on 5 ns and 2 ns; ≥200 mV<sub>p-p</sub> on 1 ns  
*Trigger Output Signal: Slaved to marker output from 5 s through 100 ns . Remains at 100 ns for all faster markers
* Trigger Output Signal: Slaved to marker output from 5 s through 100 ns. Remains at 100 ns for all faster markers
{| class="wikitable"
:{| class="wikitable"
! Internal Reference !! Standard - 1MHZ !! Option:1 - 5 MHz
! Internal Reference !! Standard - 1MHZ !! Option:1 - 5 MHz
|-
|-
Line 22: Line 22:
| Setability || 1E-7 || 5E-9  
| Setability || 1E-7 || 5E-9  
|}
|}
* External Reference Input:  1 MHz; 5 MHz; 10 MHz; TTL compatible (Internally hard wired so output frequencies counted down to 1 MHz)
* External Reference Input:  1 MHz; 5 MHz; 10 MHz; TTL compatible (Internally hard wired so output frequencies counted down to 1 MHz)
* Error Readout Range: to ±7,5%
* Error Readout Range: to ±7.5%
* Error Readout accuracy: One digit (±0,1%-points)
* Error Readout accuracy: One digit (±0.1%-points)
* Net Weight: 1 kg
* Net Weight: 1 kg
* Dimensions: 66,8 mm (w/B) x 285,3 mm (d/T) 125,9 mm (h/H)
* Dimensions: 66.8 mm × 285.3 mm (d/T) × 125.9 mm (w/d/h)


==Repair Issues==
==Repair Issues==
* Check for +15V and adjust if not between 14,3 V and 15,7 V
* Check for +15 V and adjust if not between 14.3 V and 15.7 V
* If +5V is not in between 4,94 V and 5,46 V check U626 (LM741 OpAmp). The old OpAmps tend to fail.
* If +5 V is outside 4.94 V 5.46 V, check U626 (LM741) old opamps are prone to failure.
* A lot of ICs are placed in non gold plated IC sockets. Contact problems can occure. Removing and inserting ICs helps.
* A lot of ICs are placed in non gold plated IC sockets. Contact problems can occur. Removing and inserting ICs helps.
* Mounting of A1 board to frame should be done with washers in between, especially near the rear connector. Shorts to conductor tracks can occure otherwise.
* A1 board should be mounted to frame only with washers inbetween, especially near the rear connector. Shorts to conductor tracks can occur otherwise.