Line 9: Line 9:
{| class="wikitable"
{| class="wikitable"
|-
|-
! Tek P/N
! width="80px"|Tek P/N
! Contacts
! Contacts
! Coil
! Coil
Line 15: Line 15:
! Replacement
! Replacement
! Note
! Note
|-
| 108-0599-00 || SPST (reed) ||  ||  [[7T11]]:  A3K31,A3K32,A3K70,A3K71,A3K80  || ||
|-
|-
| 148-0034-00 || DPDT ||  15 V 600 Ω  || [[7A11]]: K401,K403,K405,K407,K411,K413,K415,K417,K431<br />[[7A13]]: K47,K48,K480,K490<br />[[7A14]]: K50,K62,K330<br />[[7B70]], [[7B71]]: K6,K44,K48,K138,K780 <br /> [[7904]](A) Opt. 2: K802,K805,K812,K815 || AXICOM V23079-D2003-B301 (Ref. 2)<br />[[Media:Omron G6 relay.jpg|Omron G6N, G6S||]]
| 148-0034-00 || DPDT ||  15 V 600 Ω  || [[7A11]]: K401,K403,K405,K407,K411,K413,K415,K417,K431<br />[[7A13]]: K47,K48,K480,K490<br />[[7A14]]: K50,K62,K330<br />[[7B70]], [[7B71]]: K6,K44,K48,K138,K780 <br /> [[7904]](A) Opt. 2: K802,K805,K812,K815 || AXICOM V23079-D2003-B301 (Ref. 2)<br />[[Media:Omron G6 relay.jpg|Omron G6N, G6S||]]
Line 28: Line 30:
| [[148-0043-00]] || DPDT || 24 V 1325 Ω|| || ||
| [[148-0043-00]] || DPDT || 24 V 1325 Ω|| || ||
|-
|-
| 148-0043-01 || DPDT || 24 V 1325 Ω|| || ||
| 148-0043-01 || DPDT || 24 V 1325 Ω|| || ||
|-
|-
| 148-0044-00 || DPDT || 12 V 425 Ω|| || ||
| 148-0044-00 || DPDT || 12 V 425 Ω|| || ||
Line 50: Line 52:
| 148-0087-00 || SPDT || 90 mW ||  [[7L12]]: K300,K353,K356,K1200  || ||
| 148-0087-00 || SPDT || 90 mW ||  [[7L12]]: K300,K353,K356,K1200  || ||
|-
|-
| 148-0088-00 || DPDT || 15 V 1000 Ω || [[7L12]]: K281,K354,K355,K357,K1130,K1400,K1450 || || same pinout as 148-0034-00. [[7L12]] manual claims "120 mW", but print on relay (and measurement) says 15V 1000Ω which is 225 mW.
| 148-0088-00 || DPDT || 15 V 1 kΩ || [[7L12]]: K281,K354,K355,K357,K1130,K1400,K1450 || || same pinout as 148-0034-00. [[7L12]] manual claims "120 mW", but print on relay (and measurement) says 15V 1000Ω which is 225 mW.
|-
|-
| 148-0107-03 || SPDT ||  ||  TO5 replacement    || ||
| 148-0107-03 || SPDT ||  ||  TO5 replacement    || ||
Line 56: Line 58:
| 148-0107-04 ||  DPDT  ||    || TO5 replacement for 148-0054-00 ([[7A13]]: K7,K27)  || ||
| 148-0107-04 ||  DPDT  ||    || TO5 replacement for 148-0054-00 ([[7A13]]: K7,K27)  || ||
|-
|-
| 108-0599-00 || SPST (reed) ||   ||   [[7T11]]:  A3K31,A3K32,A3K70,A3K71,A3K80   || ||
| 148-0140-00 || Actuator ||     || [[:Category:2400 series scopes|2400 series]]  ||    ||
|-
 
|}
|}
''to be expanded''  
''to be expanded''  
Line 108: Line 112:
Tek 262 program card front.jpg | 11PST reed relay on [[262]] program cards (top right)
Tek 262 program card front.jpg | 11PST reed relay on [[262]] program cards (top right)
maglatch.jpg | Mag Latch Relay (from 1987 catalog)
maglatch.jpg | Mag Latch Relay (from 1987 catalog)
148-0140-00.jpg  | 148-0140-00
148-0140-00 frame.jpg | Three 148-0140-00 in a frame
</gallery>