P6150: Difference between revisions

Jump to navigation Jump to search
4 bytes removed ,  23 May 2021
no edit summary
m (Text replacement - "Category:50 Ohm Oscilloscope Probes" to "Category:50 Ω Oscilloscope probes")
No edit summary
Line 1: Line 1:
The '''Tektronix P6150''' is a 9 GHz probe for oscilloscopes with 50 Ω-inputs.
The '''Tektronix P6150''' is a 9 GHz probe for oscilloscopes with 50 Ω inputs.
It was designed for use with the [[SD-24]] and [[SD-26]] sampling heads,  
It was designed for use with the [[SD-24]] and [[SD-26]] sampling heads, but can be used with any 50 Ω instrumentation.
but can be used with any 50 Ω instrumentation.
 
The P6150 comes standard with 1x and 10x attenuators.
The P6150 comes standard with 1x and 10x attenuators.
The P6150 feeding the standard 1 meter cable (part number [[174-1341-00]])
 
feeding an [[SD-24]] produces a system rise time of 43 picoseconds.
The P6150 feeding the standard 1 meter cable (part number [[174-1341-00]]) feeding an [[SD-24]] produces a system rise time of 43 picoseconds.
When the optional 22 cm cable (part number [[174-1120-00]]) is used instead of the
 
1 meter cable, rise time drops to 30 picoseconds.
When the optional 22 cm cable (part number [[174-1120-00]]) is used instead of the 1 meter cable, rise time drops to 30 picoseconds.
In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF,  
 
input resistance of 500 Ω, and maximum input voltage of 12.5 V<sub>RMS</sub>.
In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF, input resistance of 500 Ω, and maximum input voltage of 12.5 V<sub>RMS</sub>.


==Manuals==
==Manuals==
* [http://w140.com/tek_p6150.pdf Tektronix P6150 Instruction Manual (PDF)]
* [[Media:070-7173-01.pdf|Tektronix P6150 Instruction Manual (PDF)]]


==Photos==
==Photos==

Navigation menu