{{Probe Sidebar | |||
|manufacturer=Tektronix | |||
|model=P6150 | |||
|summary=9 GHz passive probe | |||
|image=tek_p6150_1.jpg | |||
|caption=P6150 probe | |||
|for=50 Ω scope inputs | |||
|introduced=1989 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-7173-01.pdf|Tektronix P6150 Manual]] | |||
}} | |||
The '''Tektronix P6150''' is a 9 GHz probe for oscilloscopes with 50 Ω inputs. | The '''Tektronix P6150''' is a 9 GHz probe for oscilloscopes with 50 Ω inputs. | ||
It was designed for use with the [[SD-24]] and [[SD-26]] sampling heads, but can be used with any 50 Ω instrumentation. | It was designed for use with the [[SD-24]] and [[SD-26]] sampling heads, but can be used with any 50 Ω instrumentation. | ||
Line 4: | Line 16: | ||
The P6150 comes standard with 1x and 10x attenuators. | The P6150 comes standard with 1x and 10x attenuators. | ||
{{MissingSpecs}} | |||
The P6150 feeding the standard 1 meter cable (part number [[174-1341-00]]) feeding an [[SD-24]] produces a system rise time of 43 picoseconds. | The P6150 feeding the standard 1 meter cable (part number [[174-1341-00]]) feeding an [[SD-24]] produces a system rise time of 43 picoseconds. | ||
Line 10: | Line 23: | ||
In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF, input resistance of 500 Ω, and maximum input voltage of 12.5 V<sub>RMS</sub>. | In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF, input resistance of 500 Ω, and maximum input voltage of 12.5 V<sub>RMS</sub>. | ||