|designers=Ron Olson
|designers=Ron Olson
|manuals=
|manuals=
* [https://w140.com/mmm/tek-1a1-early.pdf Tektronix 1A1 Manual (early) (PDF)]
* [[Media:070-378.pdf|Tektronix 1A1 Manual (early)]] (bad-OCR)
* [https://w140.com/mmm/tek-1a1-late.pdf Tektronix 1A1 Manual (late) (PDF)]
* [[Media:070-0885-00.pdf|Tektronix 1A1 Manual (late)]] (bad-OCR)
<!-- * [http://w140.com/tek_fcp/tek_type_1a1_factory_cal_proc.pdf Tektronix 1A1 Field Recalibration Procedure (PDF)] -->
* [[Media:tek_1a1_field_cal_proc.pdf|Tektronix 1A1 Field Recalibration Procedure]] (OCR)
* [https://w140.com/Tektronix_1A1_SN20000up_german_short_version_300dpi.pdf Tektronix 1A1 Manual SN20000-up German Short Version (PDF)]
* [[Media:tek_1a1_sn20000up_german_short_version.pdf|Tektronix 1A1 Manual SN20000-up German Short Version]] (bad-OCR)
* [[Media:Tek type 1a1 cal outline.pdf|Tektronix 1A1 Calibration Outline]] (OCR)


* [[Media:070-378.pdf|Tektronix 1A1 Manual (early) (PDF, OCR, bad-OCR)]]
<!--
* [[Media:070-0885-00.pdf|Tektronix 1A1 Manual (late) (PDF, OCR, bad-OCR)]]
* [https://w140.com/mmm/tek-1a1-early.pdf Tektronix 1A1 Manual (early)]
* [[Media:tek_1a1_field_cal_proc.pdf|Tektronix 1A1 Field Recalibration Procedure (PDF, OCR)]]
* [https://w140.com/mmm/tek-1a1-late.pdf Tektronix 1A1 Manual (late)]
* [[Media:tek_1a1_sn20000up_german_short_version.pdf|Tektronix 1A1 Manual SN20000-up German Short Version (PDF, OCR, bad-OCR)]]
* [http://w140.com/tek_fcp/tek_type_1a1_factory_cal_proc.pdf Tektronix 1A1 Field Recalibration Procedure]
* [[Media:Tek type 1a1 cal outline.pdf|Tektronix 1A1 Calibration Outline (PDF, OCR)]]
* [https://w140.com/Tektronix_1A1_SN20000up_german_short_version_300dpi.pdf Tektronix 1A1 Manual SN20000-up German Short Version]
-->
}}
}}
The '''Tektronix Type 1A1''' plug-in for the [[500-series scopes]] has two channels and a −3 dB point of 50 MHz at 50 mV/Div, 28 MHz at 5 mV/Div,
The '''Tektronix Type 1A1''' plug-in for the [[500-series scopes]] has two channels and a −3 dB point of 50 MHz at 50 mV/Div, 28 MHz at 5 mV/Div,
Line 30: Line 32:


Type 1A1 uses the [[500_Series_plug-in_interface|"ALT SWEEP SLAVE PULSE" signal]] that is sent by scopes on pin 7 of the plug-in connector.   
Type 1A1 uses the [[500_Series_plug-in_interface|"ALT SWEEP SLAVE PULSE" signal]] that is sent by scopes on pin 7 of the plug-in connector.   
In a Type [[547]] mainframe, this signal allows channel 1 to be displayed using the "A" timebase  
In a Type [[547]] mainframe, this signal allows channel 1 to be displayed using the "A" timebase and channel 2 using the "B" timebase.
and channel 2 using the "B" timebase.
This is useful, for example, to view the IF and AF of a radio receiver at the same time.   
This is useful, for example, to view the IF and AF of a radio receiver at the same time.   
Even after the front-end transitioned from Nuvistors to FETs, the output amplifier continued to use Nuvistors.
Even after the front-end transitioned from Nuvistors to FETs, the output amplifier continued to use Nuvistors.
Line 37: Line 38:
Type 1A1 has an External Trigger output for mainframes prior to the [[547]] that don't support plug-in triggering, and supplies the trigger system on [[500 Series plug-in interface|pins 4/5 of the mainframe interface]].  It also has a ×10 amplified output from channel 1 that can be cascaded into the channel 2 input for 500 μV/Div sensitivity at reduced bandwidth (15 MHz).
Type 1A1 has an External Trigger output for mainframes prior to the [[547]] that don't support plug-in triggering, and supplies the trigger system on [[500 Series plug-in interface|pins 4/5 of the mainframe interface]].  It also has a ×10 amplified output from channel 1 that can be cascaded into the channel 2 input for 500 μV/Div sensitivity at reduced bandwidth (15 MHz).


Types 1A1 and [[1A2]] were [[introduced in 1964|introduced together in 1964]],  
Types 1A1 and [[1A2]] were [[introduced in 1964|introduced together in 1964]], the former for high-end use, the latter as an upgrade/replacement for [[CA|Type CA]].   
the former for high-end use, the latter as an upgrade/replacement for [[CA|Type CA]].   
Both remained available until the [[500-series scopes|500-series scope line]] was discontinued.