2467: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 50: | Line 50: | ||
==Links== | ==Links== | ||
* [https://www.youtube.com/watch?v=v9KaTgChudw Tektronix 2467B "Bright Eye (tm)" Oscilloscope – 1992 Tek | * [https://www.youtube.com/watch?v=v9KaTgChudw Tektronix 2467B "Bright Eye (tm)" Oscilloscope – 1992 Tek sales video] by vintageTek Museum @ YouTube | ||
* [https://www.youtube.com/watch?v=NjHbfbtNhyY Tektronix 2467B Oscilloscope Restoration] by NFM @ YouTube | * [https://www.youtube.com/watch?v=NjHbfbtNhyY Tektronix 2467B Oscilloscope Restoration] by NFM @ YouTube | ||
Revision as of 05:14, 10 April 2022
The 2467 and 2467B are the same as the 2465A, except that the 2465A uses a conventional CRT while the 2467 and 2467B use a micro-channel plate CRT that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The 2467 is from the penultimate generation of analog Tektronix scopes.
The horizontal amplifier was designed by Art Metz and Ken Schlotzhauer. Art Metz also worked on the triggers. Art Metz and Walt Ainsworth designed the sweeps.
Options
- Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
- Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
- Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
- Option 09 added option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
- Option 10 added a GPIB interface for remote control.
- Option 11 added two probe-power connectors on the rear panel of the instrument. Only shown in the 1987 catalogue.
Key Specifications
Bandwidth | 350 MHz (2467B: 400 MHz) |
---|---|
Sweep Rate | 500 ps/div |
Channels | Four independent channels |
Vertical | 2 mV/div vertical sensitivity |
Cursors | Delta Volts and Delta Time Cursors |
CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators |
Trigger | 500 MHz min.; Advanced Triggering with "Hands Off" Auto Level Triggering |
Input Impedance | 50 Ω/1 MΩ inputs with 50 Ω protection |
Probes | Two or four P6136 ×10 probes, 1.3 m |