Telequipment D75: Difference between revisions
No edit summary |
No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-1487-00.pdf | D75 Service Manual]] | * [[Media:070-1487-00.pdf | D75 Service Manual]] | ||
* [[Media:070-1487-10.pdf | D755 Instruction Manual]] | * [[Media:070-1487-10.pdf | D755 Instruction Manual]] | ||
}} | }} | ||
The '''Telequipment D75''' is a 50 MHz scope. It is a horizontal version of the [[Telequipment D83]] with a smaller CRT. The government version of the D75 is the [[Telequipment D755|D755]]. | The '''Telequipment D75''' is a 50 MHz scope. It is a horizontal version of the [[Telequipment D83]] with a smaller CRT. The government version of the D75 is the [[Telequipment D755|D755]]. | ||
The D75 takes two plug-ins that are also compatible with D83, [[Telequipment D63|D63]] and [[Telequipment DM63|DM63]]. | The D75 takes two plug-ins that are also compatible with [[Telequipment D83|D83]], [[Telequipment D63|D63]] and [[Telequipment DM63|DM63]]. | ||
Vertical plugins include the [[Telequipment V4|V4 dual trace amplifiers]], the [[Telequipment V3|V3 single channel differential amplifier]], the [[Telequipment V1|V1 single channel amplifier]], and the [[Telequipment V5|V5 single channel amplifier with delay line]] (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the [[Telequipment S1|S1 single timebase]] and [[Telequipment S2|S2 dual timebase]]. Calibration fixtures include the [[067-0672-00]] plug-in for the vertical slot and the [[067-0673-00]] plug-in for the horizontal slot. | Vertical plugins include the [[Telequipment V4|V4 dual trace amplifiers]], the [[Telequipment V3|V3 single channel differential amplifier]], the [[Telequipment V1|V1 single channel amplifier]], and the [[Telequipment V5|V5 single channel amplifier with delay line]] (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the [[Telequipment S1|S1 single timebase]] and [[Telequipment S2|S2 dual timebase]]. Calibration fixtures include the [[067-0672-00]] plug-in for the vertical slot and the [[067-0673-00]] plug-in for the horizontal slot. | ||
Line 35: | Line 35: | ||
{{Spec | Dimensions | Height: 136 mm, Width: 380 mm, Depth: 470 mm }} | {{Spec | Dimensions | Height: 136 mm, Width: 380 mm, Depth: 470 mm }} | ||
{{Spec | Weight | 11.4 kg }} | {{Spec | Weight | 11.4 kg }} | ||
{{Spec | Temperature limits | Operating: | {{Spec | Temperature limits | Operating: +5°C to +40°C, Non-operating: -25°C to +70°C }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Line 92: | Line 92: | ||
</gallery> | </gallery> | ||
==Components== | |||
{{ | {{Parts|Telequipment D75}} | ||
Latest revision as of 06:49, 21 September 2023
The Telequipment D75 is a 50 MHz scope. It is a horizontal version of the Telequipment D83 with a smaller CRT. The government version of the D75 is the D755.
The D75 takes two plug-ins that are also compatible with D83, D63 and DM63. Vertical plugins include the V4 dual trace amplifiers, the V3 single channel differential amplifier, the V1 single channel amplifier, and the V5 single channel amplifier with delay line (primarily intended for the DM63/D63 mainframes that have no built-in delay lines, whereas D75/D83 do). Timebase plugins include the S1 single timebase and S2 dual timebase. Calibration fixtures include the 067-0672-00 plug-in for the vertical slot and the 067-0673-00 plug-in for the horizontal slot.
Key Specifications
Bandwidth | DC Coupled DC to 50 MHz (−3 dB) and AC Coupled 2 Hz to 50 MHz (−3 dB) |
---|---|
Risetime | 7 ns |
Deflection | 5 mV/div to 20 V/div in 12 calibrated steps (1−2−5 sequence) |
Timebase | 2 s/div (B: 1 s/div) ) to 100 ns/div, 1−2−5 |
Input impedance | 1 MΩ // 29 pF |
Max. input | max. 400 V DC + AC peak |
Trigger modes | A: Auto, DC, AC, HF Reject; B: Auto, AC |
Trigger Sources | CH1, CH2, Alternate |
Operating modes | CH1, CH2, CH1/CH2 Alt, Chopped, CH1 and CH2 added, CH2 inverted |
Sweep modes | A only, A intensified by B, B delayed by A, A and B mixed, delayed B variable or triggered, repetitive or single shot |
Delay time | 10 μs to 20 s |
Calibrator | ~1 kHz, 30 mV and 300 mV, 3 mA, square wave, ±1% voltage and current, ±20% frequency |
CRT | 154-0676-10 tube, P31 phosphor, 15 kV acceleration, 8 cm × 10 cm graticule |
Power | 100 V − 125 V in 5V steps, 200 V − 250 V in 10 V steps, selected via primary voltage selector, 40 Hz to 400 Hz, 85 VA |
Dimensions | Height: 136 mm, Width: 380 mm, Depth: 470 mm |
Weight | 11.4 kg |
Temperature limits | Operating: +5°C to +40°C, Non-operating: -25°C to +70°C |
D75 Plug-In Variations
- D75 comprises
- (a) 50MHz Dual-Channel Amplifier - Type V4
- (b) Dual Sweep Unit - Type S2A
- D751 comprises
- (a) Differential Amplifier - Type V3
- (b) Single Sweep Unit - Type S1A
- D752 comprises
- (a) Differential Amplifier - Type V3
- (b) Dual Sweep Unit - Type S2A
- D755 comprises
- (a) 50MHz Dual-Channel Amplifier - Type V4
- (b) Dual Sweep Unit with X-Y facility - Type S2C
Standard Options
- Option 4
- P7 C.R.T. and amber filter fitted in place of P31 C.R.T. and blue filter
- Option 6
- Supplied as 115V and fitted with U.S.A. power cord
Special Types
There was a special version of this oscilloscope for post offices, the Post Office Oscilloscope Type 16A. This version had a build in graticule illumination with a brightness control knob on the back panel behind the ETH transformer.
Links
Internals
According to this posting, the CRT is a 154-0676-10 Tektronix CRT, the same as in the 465.
Pictures
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75
-
Telequipment D75 with V4 and S2A Plug-ins
-
Telequipment D75 with V4 and S2A Plug-ins
-
Telequipment D75 with V4 and S2A Plug-ins
-
Telequipment D75 with V4 and S2A Plug-ins
-
Telequipment D75 with V4 and S2A Plug-ins
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit (front view)
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit (back view)
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit (top view)
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit (top view without cover)
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit (bottom view)
-
Telequipment D75 with V4 amplifier and S2A dual sweep unit (bottom view without cover)
Components
Some Parts Used in the Telequipment D75
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0731-00 | 154-0731-00 • 154-0731-01 • 154-0731-02 • 154-0731-04 | CRT | CRT | Telequipment D75 • 455 • 465 • 465B • 468 |
T4650 | 154-0676-00 • 154-0676-05 • 154-0676-10 • 154-0676-14 | CRT | CRT | 465 • Telequipment D75 • Telequipment D755 |