7M13: Difference between revisions
No edit summary |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 43: | Line 43: | ||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/readout_unit_7M13.htm Tek 7M13 page @ amplifier.cd] | * [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/readout_unit_7M13.htm Tek 7M13 page @ amplifier.cd] | ||
* [http://www.barrytech.com/tektronix/tek7000/tek7m13.html Tek 7M13 page @ barrytech.com] | * [http://www.barrytech.com/tektronix/tek7000/tek7m13.html Tek 7M13 page @ barrytech.com] | ||
{{Documents|Link=7M13}} | |||
==Prices== | ==Prices== | ||
Line 60: | Line 61: | ||
|- | |- | ||
! In 2022 Dollars | ! In 2022 Dollars | ||
|align=right| $2,300 | |||
|align=right| $2,300 | |align=right| $2,300 | ||
|align=right| $2,200 | |align=right| $2,200 | ||
|align=right| $ | |align=right| $3,200 | ||
|- | |- | ||
|} | |} | ||
Line 80: | Line 81: | ||
</gallery> | </gallery> | ||
{{ | ==Components== | ||
{{Parts|7M13}} | |||
[[Category:7000 series special-function plugins]] | [[Category:7000 series special-function plugins]] |
Latest revision as of 06:05, 12 October 2023
The Tektronix 7M13 is a "Readout Unit" that allows the user to enter text into the scope's readout system for that module slot. It is intended to include identifying text and picture numbers for photographic documentation.
A built-in camera counter displays a pre-settable count in the second (lower) readout channel, which can be advanced manually by push-button or automatically by the camera shutter. The only editing function provided is to overwrite the character just entered (by holding the MODIFY button). To correct other errors, one needs to erase the display field.
Key Specifications
Character positions | 2 fields (top, bottom) of 10 characters each |
---|---|
Camera counter | 0-99, lower field only; ground contact closure input |
Internals and Repair Issues
The 7M13 is relatively simple and robust electrically, consisting mostly of 74xx TTL logic. However, there can be electromechanical problems due to the number of switches. For example, a 7M13 may appear unresponsive if the "(P)RESET" button for the camera counter is not fully released.
The 7M13 uses four 7489 TTL 16×4 RAMs to store the characters entered, and four 155-0038-01 Tek-made D/A converter chips to drive the analog row/column readout lines. One RAM and D/A each are assigned to row and column readout signals in each channel, and are addressed by a counter synchronized to the readout time slot pulses. In other words, characters are not stored as ASCII bytes, but as row/column pairs matching the readout system's character set. The keyboard is arranged in a matching matrix of double-contact (DPST) keys that generate the row/column coordinates through 74147 priority encoders.
Links
Documents Referencing 7M13
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1974 V6 N1.pdf | Article | CRT READOUT – Nicety or Necessity? | 1974 | 7M13 |
Prices
Year | 1974 | 1976 | 1980 | 1984 |
---|---|---|---|---|
Catalog price | $375 | $425 | $600 | $1,075 |
In 2022 Dollars | $2,300 | $2,300 | $2,200 | $3,200 |
Pictures
-
7M13 front panel
-
7M13, right side
-
7M13, left side
-
Readout example (7844 Opt.78 mainframe)
-
-
-
-
7M13 in 7633
Components
Some Parts Used in the 7M13
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
155-0038-01 | 155-0038-00 • 155-0038-01 | Monolithic integrated circuit | 5-bit current source D/A converter | 7A42 • 7D13 • 7D14 • 7M13 • T4005 |