5110: Difference between revisions
No edit summary |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar |manufacturer=Tektronix | {{Oscilloscope Sidebar | ||
model= 5110 | | |manufacturer=Tektronix | ||
summary=2 MHz mainframe | | |series=5000-series scopes | ||
image=Tek 5110.jpg | | |model=5110 | ||
caption=Tektronix 5110 | | |summary=2 MHz mainframe | ||
introduced=1976 | | |image=Tek 5110.jpg | ||
discontinued=1991 | | |caption=Tektronix 5110 | ||
manuals= | |introduced=1976 | ||
* [ | |discontinued=1991 | ||
|designers= | |||
|manuals= | |||
* [[Media:070-2134-01.pdf|Tektronix 5110 Manual]] (OCR) | |||
}} | }} | ||
The '''Tektronix 5110''' is a 5000-series three-bay mainframe. | The '''Tektronix 5110''' is a 5000-series three-bay mainframe. | ||
Earlier incarnations of it were known as [[5103|5103N]] and [[D10]]. It has a large | Earlier incarnations of it were known as [[5103|5103N]] and [[D10]]. It has a large 8×10 division CRT screen where each division is 0.5 in (12.7 mm) instead of the standard 1 cm per division. | ||
==Specifications== | ==Specifications== | ||
Line 19: | Line 22: | ||
P31 [[phosphor]] was standard. P7 and P11 were optional. CRT acceleration voltage is 3,500 V. There is no post-deflection acceleration. | P31 [[phosphor]] was standard. P7 and P11 were optional. CRT acceleration voltage is 3,500 V. There is no post-deflection acceleration. | ||
CRTs: | |||
* [[154-0633-00]] (B010100-B069999), [[154-0633-05]] (B070000-B103610), [[154-0633-10]] (B103611+) | |||
* [[154-0633-08]] (B010100-B103610, Opt.76, P7) | |||
* [[154-0633-13]] (B103611+, Opt.76, P7) | |||
* [[154-0633-09]] (B010100-B103610, Opt.78, P11) | |||
* [[154-0633-14]] (B103611+, Opt.78, P11) | |||
==Links== | |||
{{Documents|Link=5110}} | |||
==Prices== | ==Prices== | ||
1990 | {| class="wikitable" | ||
|- | |||
! Year | |||
! 1976 | |||
! 1990 | |||
! 1991 | |||
|- | |||
! Catalog price | |||
|align=right| $ | |||
|align=right| $2,420 | |||
|align=right| $ | |||
|- | |||
! In 2023 Dollars | |||
|align=right| $ | |||
|align=right| $5,700 | |||
|align=right| $ | |||
|- | |||
|} | |||
==Internals== | ==Internals== | ||
This oscilloscope contains three main boards. Interface Board, Power Supply (LV) and High Voltage/Deflection Board. | This oscilloscope contains three main boards. Interface Board, Power Supply (LV) and High Voltage/Deflection Board. | ||
Line 36: | Line 67: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek 5110.jpg | |||
Tek_5110_Front.jpg | 5110 Front Panel | Tek_5110_Front.jpg | 5110 Front Panel | ||
Tek5110Front_2.jpg | 5110 Front Panel | Tek5110Front_2.jpg | 5110 Front Panel | ||
Line 48: | Line 79: | ||
Tek_5110_A5-Signals_Out.jpg | Tek 5110 A5 - Signals Output Board | Tek_5110_A5-Signals_Out.jpg | Tek 5110 A5 - Signals Output Board | ||
Tek_5110_A2-Single_Beam_Aux.jpg | Tek 5110 - A2 - Single Beam Auxiliary Board | Tek_5110_A2-Single_Beam_Aux.jpg | Tek 5110 - A2 - Single Beam Auxiliary Board | ||
</gallery> | </gallery> | ||
Latest revision as of 04:07, 13 December 2023
The Tektronix 5110 is a 5000-series three-bay mainframe.
Earlier incarnations of it were known as 5103N and D10. It has a large 8×10 division CRT screen where each division is 0.5 in (12.7 mm) instead of the standard 1 cm per division.
Specifications
It is specified to have a 2 MHz bandwidth with a 5A18N vertical plug-in.
The phase difference between X and Y channels is specified to be less than 1 degree at 100 kHz.
P31 phosphor was standard. P7 and P11 were optional. CRT acceleration voltage is 3,500 V. There is no post-deflection acceleration.
CRTs:
- 154-0633-00 (B010100-B069999), 154-0633-05 (B070000-B103610), 154-0633-10 (B103611+)
- 154-0633-08 (B010100-B103610, Opt.76, P7)
- 154-0633-13 (B103611+, Opt.76, P7)
- 154-0633-09 (B010100-B103610, Opt.78, P11)
- 154-0633-14 (B103611+, Opt.78, P11)
Links
Documents Referencing 5110
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1971 V3 N2.pdf | Article | The Low-Frequency Oscilloscope Goes Plug-in | Jerry Shannon • Ahne Oosterhof | 1971 | 5103N • D10 • D11 • D12 • D13 • 5110 • 5111 • 5112 • 5113 • 5A24N • 5A23N • 5B13N • 5A15N • 5A18N • 5A20N • 5A21N • 5B10N • 5B12N • C-5 |
Tekscope 1972 V4 N6 Nov 1972.pdf | Article | Servicing 5100-Series Display Units | Ken Kinman | 1972 | D10 • D11 • D12 • D13 • D15 • 5110 • 5111 • 5112 • 5113 • 5115 |
Prices
Year | 1976 | 1990 | 1991 |
---|---|---|---|
Catalog price | $ | $2,420 | $ |
In 2023 Dollars | $ | $5,700 | $ |
Internals
This oscilloscope contains three main boards. Interface Board, Power Supply (LV) and High Voltage/Deflection Board. The Interface board is behind the plug-in Bays and contains basic trace/circuit to collect the signals from the Plug-ins. Single Beam Aux Board - used to combine vertical signals from both Vertical plug-ins - is mounted behind the Interface board in a slot. Optional "Signals out board" is also mounted behind the interface board - used to buffer output signals to the Co-Ax connectors behind the chassis. HV Deflection board contains the Vertical and Horizontal stages driving CRT, Unblanking and CRT HV Circuit. LV Power supply board mounted at the bottom provides regulated +30, -30, +5 and unregulated +38, -38, +200. CRT heater is powered from main transformer.
Links
Pictures
-
-
5110 Front Panel
-
5110 Front Panel
-
Tek 5110 Rear Panel
-
5110 Under Chassis
-
5110 LH W/O Cover
-
5110 Top W/O Cover
-
Tek 5110 A3 Interface Board
-
Ten 5110 A4 Board
-
Tek 5110 A1 - HV Deflection Board
-
Tek 5110 A5 - Signals Output Board
-
Tek 5110 - A2 - Single Beam Auxiliary Board