'''General Radio 874 (GR-874)''' connectors are hermaphroditic (asexual) coaxial RF connectors developed by [[wikipedia:Eduard Karplus|Eduard Karplus]] at [[General Radio]] in the late 1940s, initially for applications up to "4500 Mc" (4.5 GHz).
'''General Radio 874 (GR-874)''' connectors are hermaphroditic (asexual) coaxial RF connectors developed by [[grwiki:Eduard Karplus|Eduard Karplus]], [[grwiki:Harold M. Wilson|Harold M. Wilson]] and [[grwiki:William R. Thurston|William R. Thurston]] at [[General Radio]] in the late 1940s, initially "for applications up to 4500 Mc" (4.5 GHz).
It first appeared in the General Radio Catalog L of 1948.
 
They first appeared in the [[grwiki:Catalogs|General Radio Catalog L of 1948]]. The original versions were friction-supported, in 1961 a locking series was introduced.


GR-874 connectors are carefully engineered to keep a constant impedance throughout the signal path, by varying connector diameters between free-air and dielectrically supported sections.  These connectors therefore exhibit very little reflection and are well suited for frequencies up to 9 GHz and pulse applications. For higher frequencies a smaller connector is required to avoid the excitation of wave guide modes.
GR-874 connectors are carefully engineered to keep a constant impedance throughout the signal path, by varying connector diameters between free-air and dielectrically supported sections.  These connectors therefore exhibit very little reflection and are well suited for frequencies up to 9 GHz and pulse applications. For higher frequencies a smaller connector is required to avoid the excitation of wave guide modes.


Most GR-874 connectors came in 50 Ω impedance.  Versions for 75 Ω and 125 Ω were also available using the same ground shield and housing, but different (thinner) center pin geometry. The Tektronix [[519]] uses the 125 Ω GR-874 variant.  
Most GR-874 connectors came in 50 Ω impedance.  Versions for 75 Ω and 125 Ω were also available using the same ground shield and housing, but different (thinner) center pin geometry. The [[519|Tektronix 519 1-GHz oscilloscope]] uses the 125 Ω GR-874 variant.  


The regular 50 Ω version is used in the [[1S1]], [[1S2]], [[3S1]], [[3S7]], [[3S76]], [[3T7]], [[4S1]], [[4S2]], [[5T1]], [[5T1A]], [[5T3]], [[7M11]], [[N]], [[S-1]], [[S-2]], [[106]], [[109]], [[110]], [[113]], [[191]], [[261]], [[280]], [[281]], [[282]], [[R293]], [[661]], [[P6025]], [[P6032]], [[P6051]], [[017-0086-00]], [[017-0088-00]], [[035-5031-00]], [[067-506]], [[067-0511-00]], [[067-0513-00]], [[067-0578-99]], [[067-0594-00]], [[067-0832-01]], and possibly others, as well as in many adaptors, attenuators, and terminators.
The regular 50 Ω version is used in the [[1S1]], [[1S2]], [[3S1]], [[3S7]], [[3S76]], [[3T7]], [[4S1]], [[4S2]], [[5T1]], [[5T1A]], [[5T3]], [[7M11]], [[N]], [[S-1]], [[S-2]], [[106]], [[109]], [[110]], [[113]], [[191]], [[261]], [[280]], [[281]], [[282]], [[R293]], [[661]], [[P6025]], [[P6032]], [[P6051]], [[017-0086-00]], [[017-0088-00]], [[035-5031-00]], [[067-506]], [[067-0511-00]], [[067-0513-00]], [[067-0578-99]], [[067-0594-00]], [[067-0832-01]], and possibly others, as well as in many adaptors, attenuators, and terminators.


Different versions of the connector have different maximum voltage ratings; 1000 V is typical.
Different versions of the connector have different maximum voltage ratings; 1000 V is typical.
There are locking and non-locking versions.


By the 1970s, GR-874 connectors were being supplanted by SMA connectors in test equipment, see e.g. the progression from the [[S-1]] to the [[S-4]] sampling heads, also motivated by the higher bandwidth requirements.
By the 1970s, GR-874 connectors were being supplanted by SMA connectors in test equipment, see e.g. the progression from the [[S-1]] to the [[S-4]] sampling heads, also motivated by the higher bandwidth requirements.
Line 18: Line 18:
==Links==
==Links==
* [[Media:Gr874 1973 gr catalog.pdf | GR-874 Section of 1973 General Radio Catalog]]
* [[Media:Gr874 1973 gr catalog.pdf | GR-874 Section of 1973 General Radio Catalog]]
* [[grwiki:GR-874|GR-874 information at GRWiki including detailed lists of parts and equipment]]
* [[wikipedia:GR_connector|GR connector]] @ Wikipedia
* [[wikipedia:GR_connector|GR connector]] @ Wikipedia
* [[Patent US 2548457A|US Patent #2,548,457A, Coaxial connector for high-frequency transmission lines]]. Filed 10 Jan 1947, granted 10 Apr 1951.
* [http://www.mgs4u.com/RF-Microwave/General-Radio-GR-874.htm MGS sales list of GR874 hardware]
* [http://www.mgs4u.com/RF-Microwave/General-Radio-GR-874.htm MGS sales list of GR874 hardware]
* [[017-051]]/[[017-052]]/[[017-053]]/[[017-055]] adapters
* [[017-051]]/[[017-052]]/[[017-053]]/[[017-055]] adapters
* [https://www.youtube.com/watch?v=GfPKYc4XLho GR-874 Connector] @ YouTube
{{Documents|Link=GR-874 connector}}
{{Documents|Link=GR-874 connector}}
{{PatentLinks|GR-874 connector}}


==Pictures==
==Pictures==

Latest revision as of 01:43, 8 June 2024

General Radio 874 (GR-874) connectors are hermaphroditic (asexual) coaxial RF connectors developed by Eduard Karplus, Harold M. Wilson and William R. Thurston at General Radio in the late 1940s, initially "for applications up to 4500 Mc" (4.5 GHz).

They first appeared in the General Radio Catalog L of 1948. The original versions were friction-supported, in 1961 a locking series was introduced.

GR-874 connectors are carefully engineered to keep a constant impedance throughout the signal path, by varying connector diameters between free-air and dielectrically supported sections. These connectors therefore exhibit very little reflection and are well suited for frequencies up to 9 GHz and pulse applications. For higher frequencies a smaller connector is required to avoid the excitation of wave guide modes.

Most GR-874 connectors came in 50 Ω impedance. Versions for 75 Ω and 125 Ω were also available using the same ground shield and housing, but different (thinner) center pin geometry. The Tektronix 519 1-GHz oscilloscope uses the 125 Ω GR-874 variant.

The regular 50 Ω version is used in the 1S1, 1S2, 3S1, 3S7, 3S76, 3T7, 4S1, 4S2, 5T1, 5T1A, 5T3, 7M11, N, S-1, S-2, 106, 109, 110, 113, 191, 261, 280, 281, 282, R293, 661, P6025, P6032, P6051, 017-0086-00, 017-0088-00, 035-5031-00, 067-506, 067-0511-00, 067-0513-00, 067-0578-99, 067-0594-00, 067-0832-01, and possibly others, as well as in many adaptors, attenuators, and terminators.

Different versions of the connector have different maximum voltage ratings; 1000 V is typical.

By the 1970s, GR-874 connectors were being supplanted by SMA connectors in test equipment, see e.g. the progression from the S-1 to the S-4 sampling heads, also motivated by the higher bandwidth requirements.

GR-874 connectors and adapters continue to be available through IET Labs, Max-Gain Systems, Pasternack and possibly others.

Links

Documents Referencing GR-874 connector

Document Class Title Authors Year Links
GenRad Experimenter Oct 1948.pdf Article A Radically New Coaxial Connector for the Laboratory 1948
GenRad Experimenter Oct 1961.pdf Article New and Improved Coaxial Connectors 1961

Patents that may apply to GR-874 connector

Page Title Inventors Filing date Grant date Links
Patent US 2548457A Coaxial connector for high-frequency transmission lines Harold M Wilson 1947-01-10 1951-04-10

Pictures