11801: Difference between revisions
Jump to navigation
Jump to search
(year) |
(Updated discontinuation date) |
||
(37 intermediate revisions by 5 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
summary=Digital sampling scope | | |series=11800-series scopes | ||
image=Tek11801.jpg | | |model=11801 | ||
caption=Tektronix 11801 | | |summary=Digital sampling scope | ||
introduced=1989 | | |image=Tek11801.jpg | ||
discontinued= | |caption=Tektronix 11801 | ||
manuals= | |introduced=1989 | ||
* [ | |discontinued=1999<ref>See 9/1999 update date, when the 11801C became listed as discontinued, on https://web.archive.org/web/20000517211925/http://www.tek.com/Measurement/Products/catalog/11801c/index.html</ref> | ||
* [ | |designers=Murlan Kaufman;Stan Kaveckis; Agoston Agoston; John Carlson; John Rettig; Jon Lueker; Roy Lewallen | ||
* [ | |manuals= | ||
* [ | ''– 11801 –'' | ||
* [ | * [[Media:070-7041-00.pdf|11801 Service Manual]] | ||
''– 11801A –'' | |||
* [[Media:070-8025-00.pdf|11801A Quick Start]] | |||
* [[Media:070-8021-00.pdf|11801A User Reference]] (OCR) | |||
* [[Media:070-7720-01.pdf|11801A Command Reference]] | |||
* [[Media:070-7738-01.pdf|11801A Programmer Manual]] | |||
''– 11801B –'' | |||
* [[Media:070-8783-00.pdf|11801B User Manual]] | |||
* [[Media:070-8781-00.pdf|11801B Service Manual]] | |||
* [[Media:070-8784-00.pdf|11801B Programmer Manual]] | |||
''– 11801C –'' | |||
* [[Media:070-9971-01.pdf|11801C User Manual]] | |||
* [[Media:070-9972-02.pdf|11801C Service Manual]] | |||
* [[Media:070-9970-00.pdf|11801C Programmer Manual]] | |||
''– Additional Information –'' | |||
* [[Media:Tek 11801 11802 SM11 diagnostics.pdf|Tektronix 11801, 11802, and SM11 Diagnostics]] | |||
{{ROM Images}} | |||
<small> | |||
* [[Media:160-4288-05.bin|160-4288-05]] A25U611 | |||
* [[Media:160-4384-05.bin|160-4384-05]] U400 | |||
* [[Media:160-4385-05.bin|160-4385-05]] U310 | |||
* [[Media:160-4386-05.bin|160-4386-05]] U410 | |||
* [[Media:160-4394-05.bin|160-4394-05]] U300 | |||
* [[Media:160-5414-04.bin|160-5414-04]] U210 | |||
* [[Media:160-5415-04.bin|160-5415-04]] U220 | |||
* [[Media:160-5481-04.bin|160-5481-04]] U630 | |||
* [[Media:160-5482-04.bin|160-5482-04]] U730 | |||
* [[Media:160-5483-04.bin|160-5483-04]] U620 | |||
* [[Media:160-5484-04.bin|160-5484-04]] U720 | |||
* [[Media:160-5485-04.bin|160-5485-04]] U612 | |||
* [[Media:160-5486-04.bin|160-5486-04]] U712 | |||
* [[Media:160-5487-04.bin|160-5487-04]] U600 | |||
* [[Media:160-5494-04.bin|160-5494-04]] U250 | |||
* [[Media:160-5495-04.bin|160-5495-04]] U240 | |||
* [[Media:160-5502-02.bin|160-5502-02]] U602 | |||
* [[Media:160-5503-02.bin|160-5503-02]] U612 | |||
* [[Media:160-5620-04.bin|160-5620-04]] U700 | |||
* [[Media:160-6517-02.bin|160-6517-02]] U230 | |||
* [[Media:160-6518-02.bin|160-6518-02]] U240 | |||
</small> | |||
}} | }} | ||
The '''Tektronix 11801''' is a digital sampling oscilloscope that takes [[:Category:11800 series sampling plugins|11800 series plug-in sampling modules]]. | The '''Tektronix 11801''' is a digital sampling oscilloscope that takes four [[:Category:11800 series sampling plugins|11800 series plug-in sampling modules]]. | ||
Input channel capacity can be expanded up to 68 sampling modules (136 channels) using up to four [[SM-11| SM-11 Multi-Channel Units]] if option 1M is installed in the 11801. | |||
The 11801 design team included [[Murlan Kaufman]], [[Stan Kaveckis]], [[Agoston Agoston]], [[John Carlson]], [[John Rettig]], [[Jon Lueker]], and [[Roy Lewallen]]. | |||
The 11801A update was introduced in 1991, the 11801B in 1994, and the 11801C by 1997. | |||
The [[CSA803]] is effectively a variant of the 11801. | |||
{{BeginSpecs}} | |||
{{Spec | Vertical Resolution | 8 bits − 25 points/div }} | |||
{{Spec | Input Sensitivity | 2 to 255 mV/div in 1 mV/div steps}} | |||
{{Spec | Record Duration | 10 ps to 50 ms}} | |||
{{Spec | Record Length | 512, 1024, 2048, 4096, 5120 samples}} | |||
{{Spec | Sample Rate | up to 200 kHz}} | |||
{{Spec | Jitter | 1.1 ps RMS + 4 ppm of position (typical) }} | |||
{{Spec | Maximum Trigger Input | 1 V<sub>p-p</sub> (1x), 10 V<sub>p-p</sub> (10x), 2.5 V<sub>p-p</sub> prescaler }} | |||
{{Spec | Trigger Sensitivity | 50 mV, DC − 4 GHz, AC coupled trigger prescaler to 10 GHz}} | |||
{{Spec | CRT | | |||
* Plain 11801: 9" monochrome, touch screen | |||
* 11801A/B/C: 8½" color, touch screen }} | |||
{{EndSpecs}} | |||
==Software== | ==Software== | ||
* Tekdump screen capture software for Unix written by Steve Tell: [http://www.cs.unc.edu/Research/msl/tekdump.html Web page] / [ | * Tekdump screen capture software for Unix written by Steve Tell: [http://www.cs.unc.edu/Research/msl/tekdump.html Web page] / [[Media:Steve_tell_tekdump.tar|Download]] | ||
* [http://w140.com/joel_koltner_tsc.tar.gz TSC screen capture portable software written by Joel Koltner] | * [http://w140.com/joel_koltner_tsc.tar.gz TSC screen capture portable software written by Joel Koltner] | ||
== | ==Prices== | ||
* 1990: $23,500 (~$55,300 in 2023 dollars) | |||
[[ | ==Links== | ||
* [http://www.ko4bb.com/getsimple/index.php?id=manuals&dir=01_ROM_Images_and_Drivers/Tek_11801_ROMs Tek 11801 ROMs] / [http://www.ko4bb.com/getsimple/index.php?id=manuals&dir=Tektronix/Tektronix_-_11801_Digital_Sampling_Oscilloscope Manuals] @ KO4BB | |||
{{Documents|Link=11801}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | |||
11801_front.jpg|11801 with monochrome screen | |||
Tek 11801a trace.jpg|11801A | |||
Tek 11801a rear1.jpg|11801A option 1M | |||
Tek 11801a rear2.jpg|11801A option 1M | |||
Tek 11801c on sm-11.jpg|11801A option 1M on top of [[SM-11]] | |||
Tek 11801c with SD-24 installed.jpg|11801C with SD-24 head installed | |||
</gallery> | |||
==References== | |||
<references /> | |||
[[Category: | [[Category:11800 series mainframes]] | ||
[[Category:Sampling | [[Category:Digital Sampling scopes]] | ||
Latest revision as of 12:06, 17 December 2024
The Tektronix 11801 is a digital sampling oscilloscope that takes four 11800 series plug-in sampling modules. Input channel capacity can be expanded up to 68 sampling modules (136 channels) using up to four SM-11 Multi-Channel Units if option 1M is installed in the 11801.
The 11801 design team included Murlan Kaufman, Stan Kaveckis, Agoston Agoston, John Carlson, John Rettig, Jon Lueker, and Roy Lewallen.
The 11801A update was introduced in 1991, the 11801B in 1994, and the 11801C by 1997.
The CSA803 is effectively a variant of the 11801.
Key Specifications
Vertical Resolution | 8 bits − 25 points/div |
---|---|
Input Sensitivity | 2 to 255 mV/div in 1 mV/div steps |
Record Duration | 10 ps to 50 ms |
Record Length | 512, 1024, 2048, 4096, 5120 samples |
Sample Rate | up to 200 kHz |
Jitter | 1.1 ps RMS + 4 ppm of position (typical) |
Maximum Trigger Input | 1 Vp-p (1x), 10 Vp-p (10x), 2.5 Vp-p prescaler |
Trigger Sensitivity | 50 mV, DC − 4 GHz, AC coupled trigger prescaler to 10 GHz |
CRT |
|
Software
- Tekdump screen capture software for Unix written by Steve Tell: Web page / Download
- TSC screen capture portable software written by Joel Koltner
Prices
- 1990: $23,500 (~$55,300 in 2023 dollars)
Links
- Tek 11801 ROMs / Manuals @ KO4BB
Documents Referencing 11801
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
85W-8882.pdf | Application Note | Z-Profile Algorithm | 1993 | SD-24 • 11801 • 11802 • CSA803 |
Pictures
-
11801 with monochrome screen
-
11801A
-
11801A option 1M
-
11801A option 1M
-
11801A option 1M on top of SM-11
-
11801C with SD-24 head installed
References