262: Difference between revisions
No edit summary |
No edit summary |
||
(17 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
The Tektronix 262 is a programmer for the Tektronix [[6R1]] and [[6R1A]] digital plug-ins for the [[567]] [[sampling oscilloscope]]. | {{Instrument Sidebar | ||
It connects via a cable to J34 on the 6R1 or 6R1A. | |manufacturer=Tektronix | ||
Small printed circuit boards called program cards fit into slots in a bus inside the 262. | |model=262 | ||
Each of these cards specifies one measurement. | |class=Controller | ||
These program cards are configurable by the user. | |series= | ||
|summary=Programmer for [[6R1]] and [[6R1A]] | |||
|image=Tek 262 front.jpg | |||
|caption=Tek 262 Front | |||
|introduced=1963 | |||
|discontinued=1972 | |||
|designers= | |||
|manuals= | |||
* [[Media:070-399.pdf|Tektronix 262 Manual]] | |||
* [https://w140.com/tek_262_1968_catalog.pdf Tektronix 262 in 1968 Catalog] | |||
* [[Media:070-457.pdf|Tektronix BCD Limit Converters for the 262]] | |||
}} | |||
The '''Tektronix 262''' is a programmer for the Tektronix [[6R1]] and [[6R1A]] digital plug-ins for the [[567]] [[sampling oscilloscope]] or the [[261]] relay box, or the [[S-311]], [[S-300]], or [[S-301]] plug-ins. | |||
It connects via a cable to J34 on the 6R1 or 6R1A. Small printed circuit boards called program cards fit into slots in a bus inside the 262. | |||
Each of these cards specifies one measurement. These program cards are configurable by the user. | |||
The 262 has slots for up to eight program cards. | The 262 has slots for up to eight program cards. | ||
They are activated one at a time, either | They are activated one at a time, either manually by pressing program selection switches on the front panel of the 262, or by having the 262 execute the measurements automatically in sequence, or the measurements can be activated remotely when the 262 is slaved to another 262. | ||
manually by pressing program selection switches on the front panel of the 262, | |||
or by having the 262 execute the measurements automatically in sequence, | |||
or the measurements can be activated remotely when the 262 is slaved to another 262. | |||
The 262 was discontinued after 1971. | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek 262 front.jpg|Front | |||
Tek 262 front left.jpg|Front Left | |||
Tek 262 front left2.jpg|Fromt Left | |||
Tek 262 front right.jpg|Front Right | |||
Tek 262 top internal1.jpg|Top Internal | |||
Tek 262 top internal 34.jpg|Top Internal | |||
Tek 262 program card front.jpg|Program Card | |||
Tek 262 program card rear.jpg|Program Card | |||
Tek 262 program card relay1.jpg|Program Card Relay | |||
Tek 262 program card 018-0007-00 front.jpg|Program Card v2 | |||
Tek 262 program card 018-0007-00 back.jpg|Program Card v2 | |||
Tek 262 logic card front.jpg|Logic Card | |||
Tek 262 logic card back2.jpg|Logic Card | |||
Tek 262 synchronizer card front.jpg|Synchronizer Card | |||
Tek 262 synchronizer card back.jpg|Synchronizer Card | |||
Tek 262 regulator board front.jpg|Regulator Card | |||
Tek 262 regulator board rear.jpg|Regulator Card | |||
Tek 262 counter card front.jpg|Counter Card | |||
Tek 262 counter card back.jpg|Counter Card | |||
Tek 262 comparator card front.jpg|Comparator Card | |||
Tek 262 comparator card back.jpg|Comparator Card | |||
Tek 262 right front cards.jpg|Right Front Cards | |||
Tek 262 ps top internal.jpg|Power Supply | |||
Tek 262 rear left wiring internal.jpg|Left Rear Connector Wiring | |||
Tek 262 rear right wiring internal.jpg|Right Rear Connector Wiring | |||
Tek 262 rear left.jpg|Rear Left | |||
Tek 262 rear right.jpg|Rear Right | |||
Tek 262 rear2.jpg|Rear | |||
Tek 262 program switch internal.jpg|Program Switch Internal | |||
Tek 262.jpg|Front view | |||
Tek 262 rear.jpg|Rear view | |||
Tek 262 inside.jpg|Inside view | |||
Tek 262 limit lights internal.jpg | |||
Tek 262 card rear.jpg|programming card | |||
Tek 262 card front2.jpg|programming card | |||
</gallery> | </gallery> | ||
[[Category: | [[Category:Controllers]] |
Latest revision as of 19:33, 9 March 2024
The Tektronix 262 is a programmer for the Tektronix 6R1 and 6R1A digital plug-ins for the 567 sampling oscilloscope or the 261 relay box, or the S-311, S-300, or S-301 plug-ins.
It connects via a cable to J34 on the 6R1 or 6R1A. Small printed circuit boards called program cards fit into slots in a bus inside the 262. Each of these cards specifies one measurement. These program cards are configurable by the user.
The 262 has slots for up to eight program cards. They are activated one at a time, either manually by pressing program selection switches on the front panel of the 262, or by having the 262 execute the measurements automatically in sequence, or the measurements can be activated remotely when the 262 is slaved to another 262.
The 262 was discontinued after 1971.
Pictures
-
Front
-
Front Left
-
Fromt Left
-
Front Right
-
Top Internal
-
Top Internal
-
Program Card
-
Program Card
-
Program Card Relay
-
Program Card v2
-
Program Card v2
-
Logic Card
-
Logic Card
-
Synchronizer Card
-
Synchronizer Card
-
Regulator Card
-
Regulator Card
-
Counter Card
-
Counter Card
-
Comparator Card
-
Comparator Card
-
Right Front Cards
-
Power Supply
-
Left Rear Connector Wiring
-
Right Rear Connector Wiring
-
Rear Left
-
Rear Right
-
Rear
-
Program Switch Internal
-
Front view
-
Rear view
-
Inside view
-
-
programming card
-
programming card