The Tektronix Type 3T4 is a [[sampling oscilloscope|sampling]] sweep plug-in
{{Plugin Sidebar
for [[560-series scopes]] that is  
|manufacturer=Tektronix
remotely programmable, allowing computer-controlled measurements
|series=560-series scopes
of high-speed repetitive waveforms.  It interfaces with a
|type=3T4
[[6R1A]] plug-in in a Type [[567]] scope.  It was [[introduced in 1965]].
|summary=Programmable sampling sweep plug-in
|image=Tek 3t4 front.jpeg
|caption=3T4 Programable Sampling Sweep
|designers=
|introduced=1965
|discontinued=(?)
|manuals=
* [[Media:070-0439-00.pdf|Tektronix 3T4 Manual]]
* [[Media:Tek 3t4 cal outline.pdf|Tektronix 3T4 Calibration Outline]] (OCR)
}}
The '''Tektronix 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms.  It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope.  It was [[introduced in 1965]].


The equivalent-time sweep rate ranges from 1ns/div to 200us/div.  There is a
The [[283]] real-time adapter enables real-time sweeps with a 3T4.
10x calibrated horizontal magnification mode that can be selected, providing
100ps/div horizontal scale.  The maximum
trigger frequency is 1GHz.  The sweep can be controlled by the staircase ramp generator
in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent
to the 3T4.


The remotely programmable functions are
{{MissingSpecs}}
<ul>
 
<li>Equivalent-time sweep rate
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. 
<li>Delay time
There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale.  maximum trigger frequency is 1 GHz. 
<li>Samples per sweep
<li>Normal or single-display mode
<li>Single-display start
</ul>


The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4. 


The remotely programmable functions are
* Equivalent-time sweep rate
* Delay time
* Samples per sweep
* Normal or single-display mode
* Single-display start


[[list of manuals that are needed|Manual needed]].
==Links==
* See also [[012-0101-00]]
{{Documents|Link=3T4}}


==Pictures==
<gallery>
<gallery>
Image:3t4_front.jpg|front view
3t4_front.jpg | Front View
Image:3t4_left.jpg|left view
3t4_left.jpg | Left View
Image:3t4_right.jpg|right view
3t4_right.jpg | Right View
Image:3t4_top.jpg|top view
3t4_top.jpg   | Top View
Image:3t4_bottom.jpg|bottom view
3t4_bottom.jpg| Bottom View
Image:Tek 3t4 1965 cat.jpg|Description in 1965 Tek Catalog
Tek 3t4 1965 cat.jpg | Description in 1965<br>Tektronix Catalog
Image:Smpte apr1965 3t4.png|In April 1965 SMPTE Journal
Smpte apr1965 3t4.png | In April 1965 SMPTE Journal
</gallery>
</gallery>
==Components==
{{Parts|3T4}}
[[Category:560 series plugins]]

Latest revision as of 04:34, 29 November 2023

Tektronix 3T4
Programmable sampling sweep plug-in
3T4 Programable Sampling Sweep

Compatible with 560-series scopes

Produced from 1965 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T4 is a sampling sweep plug-in for 560-series scopes that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a 6R1A plug-in in a Type 567 scope. It was introduced in 1965.

The 283 real-time adapter enables real-time sweeps with a 3T4.

Key Specifications

  • please add

The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. maximum trigger frequency is 1 GHz.

The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.

The remotely programmable functions are

  • Equivalent-time sweep rate
  • Delay time
  • Samples per sweep
  • Normal or single-display mode
  • Single-display start

Links

Documents Referencing 3T4

(no results)

Pictures

Components

Some Parts Used in the 3T4

Part Part Number(s) Class Description Used in
8056 154-0417-00 Vacuum Tube (Triode) low-voltage Nuvistor triode 422 502 W 1S1 3A7 3S3 3T4 5T3 10A1